Issue 2 06/2005
COMPANY CONFIDENTIAL
63
Copyright © 2005 Nokia. All Rights Reserved.
RH-53/54
Nokia Customer Care
Note! More than 32MB SRAM may be required in FPS-8
This concept can also be used for troubleshooting and RF calibration.
•
MJ-36 is intended for use with an external power supply.
•
MJ-36 input voltage : 6V, m12V
•
Ensure that the jumper is set open for voltage regulation before the external pow-
er supply is connected.
•
When FPS-8 is used as the power supply (4V), the jumper should be set close to
bypass regulator.
•
EM calibrations including Zocus are only done with JBV-1. Module jig MJ-36 does
not support Zocus calibration for RH-53/54
Without shielding can I208 (MJ-36 insert is
needed).
With shielding can (the insert can be
placed in the compartment).