Issue 2 06/2005
COMPANY CONFIDENTIAL
43
Copyright © 2005 Nokia. All Rights Reserved.
RH-53/54
Nokia Customer Care
Select “Calibrate” to run the selected calibrations.
Limits for Energy Management Calibration:
If values shown are within limits select “Save To Phone” to save the values in the phone.
NOTE! Only the values of the checked tunings (Battery size, Battery Temperature etc…) are
saved.
Close the “Energy Management Calibration” – dialog to end tuning.
You must manually switch the phone on after exiting “Energy Management Calibration” – dia-
log.
Table 1:
Parameter
Min.
Max
Note
ADC gain
25400
29000
VBatt, BSI, BTemp
DC offset
-50
50
ADC voltage offset
BSI gain
970
1100
ADC BSI calibration gain
BTEMP gain
2075
2275
ADC BTEMP calibration
gain
VBAT gain
10000
11000
ADC VBATT Voltage gain
VBAT offset
2300
2900
ADC VBATT Voltage offset
scale
VCHAR
58000 62000 Charge
voltage
ICHAR
4050 4800 charge
current