RH-53/54
Nokia Customer Care
6-Disassembly and Assembly Instructions
10
COMPANY CONFIDENTIAL
Issue 2 06/2005
Copyright © 2005 Nokia. All Rights Reserved.
28.) Unlock the snaps before removing the IHF Antenna
Chamber.
29.) Remove the Antenna Chamber.
30.) Release the four hooks carefully by using the SRT-
6.
31.) Separate the C2-Cover from LCD CAN Assy.
32.) Use tweezers when removing the Vibra Motor.
33.) Open the LCD Connector by using the SRT-6 care-
fully.
34.) Place the SRT-6 between LCD and the LCD Can as
shown in the picture and lever out the LCD carefully.
35.) Release the four springs of Key Dome Shield.