RH-53/54
Nokia Customer Care
42
COMPANY CONFIDENTIAL
Issue 2 06/2005
Copyright © 2005 Nokia. All Rights Reserved.
Baseband Tuning Operations
■
Energy Management Tuning
External power supply needed.
Energy Management (EM) Calibration is used for calibrating Battery and Charger settings of
the phone.
Preparation for EM Calibration:
- Connect the DC Cable SCB-3 between JBV-1 and Vin of the Phone for Charger calibration.
- Connect 12…15 V from the Power Supply to JBV-1.
- NOTE! Check that the connection is F-BUS (does not work with M-BUS).
Select Tuning => Energy Management Calibration.
Energy Management values to be calibrated are checked.
Select “Read from Phone” to show the current values in the phone memory and to check that
the communication with the phone works.