room
System
159
Ser
e
S
Main Broom System
Functional Description
%\XVLQJWKHOHIWOHYHURQWKHGDVKERDUGWKHPDLQEURRPVXSSRUWV\VWHPORZHUVEHFDXVHLWLVUHOHDVHGE\
a metal cable; the broom is kept pressed to the ground by two gas springs that ensure the contact with the
ground at all times.
The electric motor transmits the motion to the main broom by means of a drive belt connected to an hexagonal
driver that supports the broom.
The machine must be moving otherwise the main broom motor does not run.
7KHIURQWVNLUWOLIWLQJSHGDODOORZVWRFROOHFWPHGLXPVL]HZDVWHPDWHULDOVFDQVER[HVHWF7KHIURQWVNLUW
PXVWEHOLIWHGRQO\ZKHQQHFHVVDU\EHFDXVHLWDIIHFWVWKHRSHUDWLRQRIWKHGXVWFRQWUROV\VWHP
The main broom motor (M4) is supplied by the electromagnetic switch (ES1) and protected by the fuse (FA).
The electromagnetic switch (ES1) is activated by the dashboard electronic board (EB2) according to the infor-
PDWLRQUHFHLYHGE\VHQVRU6PDLQEURRPFRQWUROOHYHUSRVLWLRQPDFKLQHPRYLQJVLJQDOLQIRUPDWLRQWKDW
(%UHFHLYHVIURP(%OLIWHGKRSSHUVLJQDOEDWWHU\YROWDJHVHH'DVKERDUG(OHFWURQLF%RDUG6SHFLÀFDWLRQV
step d).
7KHIXVH)$DFWLYDWHVLQFDVHRIVKRUWFLUFXLWRUEORFNHGURWRUEXWLQFDVHRIRYHUORDGWKHGDVKERDUGHOHF
-
WURQLFERDUG(%UHDGVWKHYROWDJHGURSRQWKHIXVHWKXVGHDFWLYDWLQJ(6EHIRUHWKHIXVHFDQDFWLYDWHVHH
0DLQ%URRP0RWRU3URWHFWLRQLQ'DVKERDUG(OHFWURQLF%RDUG6SHFLÀFDWLRQV7KHDFWLYDWLRQRIDQHOHFWURQLF
protection is indicated by the main broom overload warning light (A).
A
P200235
Wiring Diagram
CONTROL PANEL ELECTRONIC BOARD (EB2)
J1.1 - Electronic board power
J1.4 - Broom fuse voltage drop r
J1.5 - Broom fuse voltage drop reading -
J1.2 - Broom activation lever signal
J1.10 - Broom electromagnetic switch power supply
J1.9 - Electronic board power supply -
MAIN BROOM
ELECTROMAGNETIC
SWITCH (ES1)
DISPLAY ELECTRONIC
BOARD FUSE (F3)
MAIN BROOM
MOTOR
MAIN BROOM
FUSE (FA)
MAIN BROOM
ELECTROMAGNETIC
SWITCH (ES1)
MAIN BROOM LEVER
SENSOR (S2)
POSITIVE SIGNAL
(FROM MACHINE ON K4 )
BATTERY NEGATIVE TERMINAL
V
M4
P200168