room
System
176
Ser
e
S
Main Broom Motor Carbon Brush Check/Replacement
Disassembly
1. Remove the main broom motor (see the procedure in the previous paragraph).
2.
$WWKHZRUNEHQFKUHPRYHWKHQXWV$DQGWKHJXDUG%RIWKHPDLQEURRPPRWRU&
3.
,IQHFHVVDU\FOHDQWKHH[WHUQDOVLGHRIWKHPRWRU&LQWKHDUHDRIWKHSURWHFWLRQEDQG'
4. Disengage the cam lever (E) and remove the protection band (D).
5. Remove the fastening screws (F) of the electrical connections of the four carbon brushes (G).
6.
5HPRYHWKHIRXUFDUERQEUXVKHV*IURPWKHLUKRXVLQJVE\GLVHQJDJLQJWKHPIURPWKHUHWDLQLQJ
springs (H).
7.
&KHFNWKHFDUERQEUXVKHV*IRUZHDU7KHFDUERQEUXVKHVDUHZRUQZKHQ
7KHFRQWDFWZLWKWKHPRWRUDUPDWXUHLVLQVXIÀFLHQW
The contact surface is not integral
The stroke is less than 0.12 in (3 mm)
The spring is broken
,QWKLVFDVHVUHSODFHDOOPRWRUFDUERQEUXVKHV
Assembly
8. Assemble the components in the reverse order of disassembly.
C
B
A
D
H
G
F
E
C
P200177
Summary of Contents for SW4000
Page 233: ......