9.10. Change between 25 bar and 40 bar in the Display
1
3
2
4
Change the display from 25 bar to 40 bar mode:
1. Turn off the main power
2. Wait for 2 minutes
3. Press the right button (3) and at the same time turn the power supply on
Check:
1. Turn off the power supply.
2. Wait for 2 minutes
3. Turn on the power supply again and press the middle/round button (2)
4. It says DUAL in the display (4)
Change the display from 40 bar to 25 bar mode:
1. Turn off the main power.
2. Wait for 2 minutes.
3. Press the ON green button (1) and at the same time turn power supply on.
Check:
1. Turn off the main power.
2. Wait for 2 minutes.
3. Turn on the power supply again and press the middle/round button (8)
4. It says STD in the Display (4).
110004582-3