background image

18

For both DT-5TXR and DT-5TFR, if you purchase a model with optional equipment, be sure to check its model, 

speci

fi

cations, and wiring method for the correct use.

Speci

fi

cations

* The user must perform cable connection.

Wiring  (Connector connection)

HOLD input circuit

ENABLE input circuit

Output circuit

䖃 㼀㼕㼙㼕㼚㼓㻌㼏㼔㼍㼞㼠

㻱㼤㼠㼑㼞㼚㼍㼘㻌㼏㼛㼚㼚㼑㼏㼠㼕㼛㼚㻌

㼑㼤㼍㼙㼜㼘㼑

㻰㼀㻙㻡㼀㼄㻾㻛㻰㼀㻙㻡㼀㻲㻾

㻰㼀㻙㻡㼀㼄㻾㻛㻰㼀㻙㻡㼀㻲㻾

㻰㼀㻙㻡㼀㼄㻾㻛㻰㼀㻙㻡㼀㻲㻾

㻱㼤㼠㼑㼞㼚㼍㼘㻌㼏㼛㼚㼚㼑㼏㼠㼕㼛㼚㻌

㼑㼤㼍㼙㼜㼘㼑

㻱㼤㼠㼑㼞㼚㼍㼘㻌㼏㼛㼚㼚㼑㼏㼠㼕㼛㼚㻌

㼑㼤㼍㼙㼜㼘㼑

Measured data

䇾㻜㻜㻜㻜㻜䇿

㻰㼍㼠㼍㻌㻝

㻰㼍㼠㼍㻌㻞

㻰㼍㼠㼍㻌㻟

㻰㼍㼠㼍㻌㻠

Hold signal

“H”
“L”

BCD output

㻴㼛㼘㼐

䇾㻜㻜㻜㻜㻜䇿

䇾㻜㻜㻜㻜㻜䇿

㻰㼍㼠㼍㻌㻝

㻰㼍㼠㼍㻌㻞

㻰㼍㼠㼍㻌㻟

㻴㼕㼓㼔㻌㼕㼙㼜㼑㼐㼍㼚㼏㼑

㻰㼍㼠㼍㻌

㻰㼍㼠㼍㻌㻠

Data out signal

“H”

“L”

㻰㼍㼠㼍㻌㼛㼡㼠

㼁㼜㼐㼍㼠㼑㼐

Enable signal

㻭㼜㼜㼞㼛㼤㼕㼙㼍㼠㼑㼘㼥

㻢㼙㼟㼑㼏

㻭㼜㼜㼞㼛㼤㼕㼙㼍㼠㼑㼘㼥

㻝㻜㻜㼙㼟㼑㼏

 Optional Equipment (Commonly Used for DT-5TXR/ DT-5TFR)

䣏䣱䣦䣧䣮

䣆䣑䣒䢯䣄䣅䣆

䣐䣒䣐䢢䣱䣲䣧䣰䢢
䣥䣱䣮䣮䣧䣥䣶䣱䣴䢢䣱䣷䣶䣲䣷䣶

䣑䣷䣶䣲䣷䣶䢢
䣥䣣䣲䣣䣥䣫䣶䣻

䣆䣅䢵䢲䣘䢢䢴䢲䣯䣃

䣑䣲䣧䣰䢢䣥䣱䣮䣮䣧䣥䣶䣱䣴䢢
䣫䣰䣲䣷䣶

䣑䣲䣧䣰䢢䣥䣱䣮䣮䣧䣥䣶䣱䣴䢢䢪䣐䣒䣐䢫䢢䣫䣰䣲䣷䣶

䣎䣑䢢䣫䣰䣲䣷䣶

䣎䣱䣣䣦䢢䣥䣣䣲䣣䣥䣫䣶䣻䢼䢢䢷䣯䣃䢢䣱䣴䢢䣯䣱䣴䣧
䢲䢢䣶䣱䢢䢳䢰䢷䣘

䣊䣋䢢䣫䣰䣲䣷䣶

䣎䣧䣣䣭䣣䣩䣧䢢䣥䣷䣴䣴䣧䣰䣶䢼䢢䢲䢰䢳䣯䣃䢢䣱䣴䢢䣮䣧䣵䣵

䣆䣣䣶䣣䢢䣱䣷䣶䣲䣷䣶

䢸䢯䣦䣫䣩䣫䣶䢢䣄䣅䣆䢢䣥䣱䣦䣧

䣆䣧䣥䣫䣯䣣䣮䢢䣲䣱䣫䣰䣶䢢
䣱䣷䣶䣲䣷䣶

䣆䣒䢢䢳䢢䣶䣱䢢䢶䢢䢪䢳䢲

䢯䢳

䢢䣶䣱䢢䢳䢲

䢯䢶

䢢䣦䣫䣩䣫䣶䣵䢫

䣅䣱䣰䣶䣴䣱䣮䢢䣱䣷䣶䣲䣷䣶

䣒䣎䣗䣕

䣖䣪䣫䣵䢢䣵䣫䣩䣰䣣䣮䢢䣥䣪䣣䣰䣩䣧䣵䢢䣫䣰䣶䣱䢢䣎䣑䢢䣹䣪䣧䣰䢢䣦䣣䣶䣣䢢
䣱䣷䣶䣲䣷䣶䢢䣫䣵䢢䣲䣱䣵䣫䣶䣫䣸䣧䢰

䣆䣖䢢䣑䣗䣖

䣑䣷䣶䣲䣷䣶䢢䣵䣫䣩䣰䣣䣮䢢䣫䣵䢢䣦䣧凐䣰䣧䣦䢢䣹䣪䣧䣰䢢䣶䣪䣫䣵䢢䣵䣫䣩䣰䣣䣮䢢䣫䣵䢢䣊䣋䢰

䣑䣘䣔

䣙䣪䣧䣰䢢䣶䣪䣧䢢䣦䣫䣵䣲䣮䣣䣻䢢䣸䣣䣮䣷䣧䢢䣥䣪䣣䣰䣩䣧䣵䢢䣫䣰䣶䣱䢢䣱䣸䣧䣴凑䣱䣹䢢
䣫䣰䣦䣫䣥䣣䣶䣫䣱䣰䢮䢢䣶䣪䣫䣵䢢䣵䣫䣩䣰䣣䣮䢢䣥䣪䣣䣰䣩䣧䣵䢢䣫䣰䣶䣱䢢䣎䣑䢰

䣅䣱䣰䣶䣴䣱䣮䢢䣫䣰䣲䣷䣶

䣊䣑䣎䣆

䣆䣣䣶䣣䢢䣫䣵䢢䣰䣱䣶䢢䣷䣲䣦䣣䣶䣧䣦䢢䣹䣪䣫䣮䣧䢢䣶䣪䣫䣵䢢䣵䣫䣩䣰䣣䣮䢢䣫䣵䢢䣎䣑䢰

䣇䣐䣃䣄䣎䣇

䣑䣷䣶䣲䣷䣶䢢䣤䣧䣥䣱䣯䣧䣵䢢䣣䣮䣮䢢䣣䣶䢢䣪䣫䣩䣪䢢䣫䣯䣲䣧䣦䣣䣰䣥䣧䢢䣹䣪䣫䣮䣧
䣶䣪䣫䣵䢢䣵䣫䣩䣰䣣䣮䢢䣫䣵䢢䣎䣑䢰

䣅䣱䣰䣰䣧䣥䣶䣱䣴䢢䣷䣵䣧䣦䢬

䣝䣑䣰䢢䣆䣖䢯䢷䣖䣚䣔䢱䣆䣖䢯䢷䣖䣈䣔䢢䣵䣫䣦䣧䣟䢢䣒䣅䣕䢯䣇䢵䢸䣎䣏䣆䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢
䣝䣑䣰䢢䣶䣪䣧䢢䣲䣮䣷䣩䢢䣵䣫䣦䣧䣟䢢䣒䣮䣷䣩䢼䢢䣒䣅䣕䢯䣇䢵䢸䣕䣈䢮䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢
䣅䣱䣸䣧䣴䢼䢢䣒䣅䣕䢯䣇䢵䢸䣎䣃䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢䢢
䢪䣤䣱䣶䣪䢢䣯䣣䣰䣷䣨䣣䣥䣶䣷䣴䣧䣦䢢䣤䣻䢢䣊䣱䣰䣦䣣䢢䣅䣱䣯䣯䣷䣰䣫䣥䣣䣶䣫䣱䣰䢫

䣄䣅䣆䢢䣱䣷䣶䣲䣷䣶䢢䣣䣰䣦䢢䣦䣧䣥䣫䣯䣣䣮䢢䣲䣱䣫䣰䣶䢢䣱䣷䣶䣲䣷䣶䢢䣥䣣䣰䢢䣤䣧䢢䣵䣧䣶䢢䣶䣱䢢䣧䣫䣶䣪䣧䣴䢢䣰䣧䣩䣣䣶䣫䣸䣧䢢䣱䣴
䣲䣱䣵䣫䣶䣫䣸䣧䢢䣮䣱䣩䣫䣥䢰䢪䣗䣵䣧䢢䣨䣷䣰䣥䣶䣫䣱䣰䢢䢳䢲䢢䣶䣱䢢䣵䣧䣮䣧䣥䣶䢢䣧䣫䣶䣪䣧䣴䢢䣱䣰䣧䢰䢫

㻞㼚㼐㻌㼛㼜㼠㼕㼛㼚㻌㻔㼏㼛㼚㼚㼑㼏㼠㼛㼞㻌㼛㼡㼠㼜㼡㼠㻕

㻰㻻㻼㻙㻮㻯㻰

㻮㻯㻰㻌㼛㼡㼠㼜㼡㼠

㻵㼚㼜㼡㼠㻛

㻻㼡㼠㼜㼡㼠

㻿㼥㼙㼎㼛㼘

㻼㼕㼚㻌㻺㼡㼙㼎㼑㼞

㻿㼥㼙㼎㼛㼘

㻵㼚㼜㼡㼠㻛㻌

㻻㼡㼠㼜㼡㼠

㻻㼡㼠㼜㼡㼠

㽢 㻝㻜

㻝㻥

㽢 㻝㻜

㻻㼡㼠㼜㼡㼠

㻞㻜

㻞㻝

㻞㻞

㽢 㻝㻜

㻞㻟

㽢 㻝㻜

㻞㻠

㻞㻡

㻞㻢

㽢 㻝㻜

㻞㻣

㽢 㻝㻜

㻝㻜

㻞㻤

㻝㻝

㻞㻥

㻝㻞

㻟㻜

㻼㻸㼁㻿

㻝㻟

㻟㻝

㻰㻼㻝

㻰㼀㻌㻻㼁㼀

㻝㻠

㻟㻞

㻰㻼㻞

㻻㼂㻾

㻝㻡

㻟㻟

㻰㻼㻟

㻵㼚㼜㼡㼠

㻴㻻㻸㻰

㻝㻢

㻟㻠

㻰㻼㻠

㻱㻺㻭㻮㻸㻱

㻝㻣

㻟㻡

㻳㻺㻰

㻳㻺㻰

㻝㻤

㻟㻢

㻳㻺㻰

Summary of Contents for SHIMPO DT-5TFR

Page 1: ...Also DO NOT put any foreign matters inside the unit through these holes Otherwise abnormal heat generation or equipment malfunction can be caused DO NOT touch the unit with wet or sweaty hands for wir...

Page 2: ...Option Power Requirement Input Type HH High set point 2 output H High set point 1 output L Low set point 1 output LL Low set point 2 output For combinations of the above mentioned output levels refer...

Page 3: ...ped only terminal block for the 1st optional equipment or connector for the 2nd optional equipment can be viewed from outside of this unit Rear Note When the connector is attached a 30 mm or more spac...

Page 4: ...unit to the panel with the attachment screws The specified torque to fasten the screws is 6 5kgf cm or less Place the unit horizontally and then insert it into the panel s attachment opening Push the...

Page 5: ...ion Be sure to use sealed wires for input connection or install them in a metal conduit as well as to keep the wires as short as possible DT 5TXR Terminal block connection diagram Note When using an N...

Page 6: ...sensor s connection wires together with strong electric cables power cable high voltage cable etc via bundling wiring in parallel or installing them in one conduit Otherwise noise is sent via a sig n...

Page 7: ...ther When the actual rpm can be checked measured the following easy method field adjustment can be used for the settings The field adjustment does not require complicated calculations Via this functio...

Page 8: ...are not necessary the default values values shown above designated upon shipping can be used as is Note 1 The high set point 2 value is displayed on the sub display A and the low set point 2 value on...

Page 9: ...e is 1000 output is turned ON and when it is 990 OFF About Display Use Function 5 Sub display s display pattern selection to select the desired display pattern from the following three Display pattern...

Page 10: ...n about the parameter function refer to page 8 For detailed information about the function refer to page 8 Note 1 The high set point 2 value is displayed on the sub display A and the low set point 2 v...

Page 11: ...he low set point 2 value on the sub B display The display system is designated via parameter 3 value to be dis played The sub displays do not display the colon Note 2 Function 10 can be set up only wh...

Page 12: ...Note 3 Functions 11 to 14 can be set up when the first optional equipment DOP FVTR or the second optional equipment DOP FVC has been installed bout Scaling Parameter 3 Scaling factor is a value obtai...

Page 13: ...hen a measuring value is smaller than the low set point 1 value Lights up when a measuring value is smaller than the low set point 2 value Designates via function 5 see page 8 Designates via function...

Page 14: ...nd DT 5TFR this mode is used to perform self diagnosis of the internal circuit LED display test key entry test The mode number is 99 Test Type Checks if the main display s LED is functioning correctly...

Page 15: ...display s first digit In the same manner press each key and 1 is displayed on the related display digit LED There is no entry test for the SET and MOD keys LED related to each key is as follows Main d...

Page 16: ...mber of pulse is one per revolution When display value is 46 8m min at 1200rpm analog output signal is 10V Minimum out put signal is 0V and update time is same as display cycle Other Parameter and Fun...

Page 17: ...f assembling the first option to DT 5TXR unit body after purchasing please note that only the options with R at the foot of model name can be connected to the unit For both DT 5TXR and DT 5TFR if you...

Page 18: ...fications and wiring method for the correct use Specifications The user must perform cable connection Wiring Connector connection HOLD input circuit ENABLE input circuit Output circuit Measured data H...

Page 19: ...and DT 5TFR if you purchase a model with optional equipment be sure to check its model specifications and wiring method for the correct use This operation manual is applicable to the following models...

Page 20: ......

Reviews: