EN
English –
1
ENGLISH
Contents
1 - WARNINGS AND GENERAL PRECAUTIONS
. . . . . . . . . . . . . . . . . . . . 1
1.1 - Safety warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 - Warnings for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.3 - Warnings for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 - PRODUCT DESCRIPTION AND INTENDED USE
. . . . . . . . . . . . . . . . . 1
3 - INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1 - Pre-installation checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.2 - Usage limitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.3 - Preparatory work prior to installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.4 - Installation of the gearmotor mod. WL1024C - WL1024 . . . . . . . . . . . . 3
3.4.1 - Establishing the length of the gearmotor arm
. . . . . . . . . . . . . . 3
3.4.2 - Installation of a gearmotor with a STANDARD LENGTH ARM
. . 3
3.4.3 - Installation of a gearmotor with a SHORTENED ARM
. . . . . . . . 4
3.5 - Installation of the multi-purpose lamp mod. WLT on the gearmotor
model WL1024C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.6 - How to remove the control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.7 - Adjusting the alignment of the gate leaves when closed . . . . . . . . . . . . 5
3.8 - Securing and releasing the gearmotor manually . . . . . . . . . . . . . . . . . . 5
4 - ELECTRICAL CONNECTIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.1 - Description of the electrical connections . . . . . . . . . . . . . . . . . . . . . . . . 5
4.2 - Connecting the power cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.3 - Connecting the gearmotor without a control unit mod. WL1024 . . . . . . 5
4.4 - Connecting other devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.5 - Addressing the connected devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.6 - Initialisation and connection check . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.7 - Recognition of the connected devices . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.8 - Recognition of the positions of the mechanical stops . . . . . . . . . . . . . . 6
4.9 - Gate leaves motion check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5 - TESTING AND COMMISSIONING
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1 - Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.2 - Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 - PROGRAMMING THE CONTROL UNIT
. . . . . . . . . . . . . . . . . . . . . . . . 7
6.1 - Level one programming (ON-OFF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.2 - Level two programming (adjustable parameters) . . . . . . . . . . . . . . . . . . 8
6.3 - Memory deletion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.4 - Special functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7 - WHAT TO DO IF... (troubleshooting guide)
. . . . . . . . . . . . . . . . . . . . . . 9
8 - FURTHER INFORMATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8.1 - Connection of the OXI radio receiver . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8.2 - Connection and installation of the back-up battery mod. PS424 . . . . . 10
8.3 - Connection of the Oview programmer . . . . . . . . . . . . . . . . . . . . . . . . 10
8.4 - Connection of the Solemyo solar power system . . . . . . . . . . . . . . . . . 10
9 - PRODUCT MAINTENANCE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
DISPOSING OF THE PRODUCT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PRODUCT TECHNICAL SPECIFICATIONS
. . . . . . . . . . . . . . . . . . . . . . . 11
Product life span
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
EC DECLARATION OF CONFORMITY
. . . . . . . . . . . . . . . . . . . . . . . . . . . 12
APPENDIX
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Instructions and warnings for the user . . . . . . . . . . . . . . . . . . . . . . . . . . . . . III
Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
1.1 - Safety warnings
• IMPORTANT!
– This manual contains important instructions and warn-
ings regarding safety.
Incorrect installation may cause serious injury. Before
commencing work, all sections of the manual must be read carefully. If in any
doubt, suspend installation and call the Nice Support Service for clarification.
• IMPORTANT!
– This manual contains important instructions. Keep it for
future maintenance work and disposal of the product.
• IMPORTANT!
– Under the latest European legislation, automatic door
and gate installations must be compliant with the standards specified in
Directive 2006/42/EC (formerly 98/37/EC) (the Machinery Directive) and
the standards EN 12445, EN 12453, EN 12635 and EN 13241-1 in partic-
ular, which enable conformity of the automated functionality to be de -
clared.
In the light of the above
, all work involving installation, con-
nection, testing and maintenance of the product must be carried out
exclusively by qualified and competent technicians!
1.2 - Warnings for installation
• Before commencing the installation, check if the product is suitable for the
desired type of use (see “Usage limitation” paragraph 3.2 and the "Product
technical specifications”). If it is not suitable, DO NOT continue with the instal-
lation.
•
All installation and maintenance work must be carried out with the au -
tomation system disconnected from the electricity supply.
If the power
disconnection device cannot be seen from where the automation system is
positioned, then before starting work a notice must be attached to the dis-
connection device bearing the words “CAUTION! MAINTENANCE IN PRO -
GRESS”.
• The Control unit must be connected to an electricity supply line equipped
with protective earthing.
• Handle the product with care during installation, taking care to avoid crush-
ing, denting or dropping it, or contact with liquids of any kind. Keep the prod-
uct away from sources of heat and naked flames. Failure to observe the
above can damage the product, and increase the risk of danger or malfunc-
tion. Should this occur, suspend installation work immediately and contact
the Nice Support Service.
• Do not modify any part of the product. Prohibited modifications can only lead
to malfunctions. The manufacturer declines all responsibility for damage re -
sulting from unauthorized changes made to the product.
• If the gate or door being automated has a pedestrian gate, then the system
must include a control device that will inhibit the operation of the motor when
the pedestrian gate is open.
• The product’s packaging material must be disposed of in full compliance with
local regulations.
1.3 - Warnings for use
• The product is not intended for use by persons, including children, with limit-
ed physical, sensory or mental capacities, or who lack experience or knowl-
edge, unless supervised or trained in the use of the product by a person
responsible for their safety.
• Any children near the automation system must be kept under supervision to
ensure that they do not play with it.
• Do not allow children to play with the fixed control devices. Keep remote con-
trol devices out of the reach of children.
WARNINGS AND GENERAL PRECAUTIONS
1
The devices comprising this product are designed to automate a gate or door
with one or two leaves.
IMPORTANT!
– Any other use apart from that
described herein, including in different environmental conditions from
those described in this manual is to be considered improper use and is
not permitted!
The principal component of the automation system comprises one or two elec-
tric gearmotors (according to the number of leaves to be automated), each
equipped with a direct current motor and epicyclic reduction gear. One of the
gearmotors (mod. WL1024C) has a control unit that controls its operation. The
Control unit consists of a board with a radio receiver for receiving the com-
mands sent by the transmitter.
The control unit is designed for connection to several devices belonging to the
Opera system, the Bluebus system and the Solemyo solar powered system.
If it is mains powered, it can house a back-up battery (mod. PS424, optional
accessory) which in the event of a power cut (electricity black-out) guarantees
that the automated device will perform certain manoeuvres in the hours that fol-
low.
In the event of a power cut, the gate leaves can be moved by releasing the
gearmotor with the dedicated key; to perform the manoeuvre manually please
see chapter 3.8.
PRODUCT DESCRIPTION AND
INTENDED USE
2
Summary of Contents for WALKY 1024
Page 2: ......
Page 88: ......
Page 96: ...X 1 2 2a 385 mm 125 mm 85 mm ...
Page 97: ...3 XI 6 7 4 5 ...
Page 98: ...XII 1 2 3 4 45 45 1 3 a c b OK OK b a 8 a a b 5 6 7 8 9 10 11 12 13 ...
Page 99: ...XIII 75 mm 1 2 3 4 5 6 7 8 9 10 12 11 9 ...
Page 100: ...XIV 10 11 12 1 2 3 4 13 ...
Page 101: ...XV 15 2 1 4 3 2 1 14 16 2 1 ...
Page 102: ...XVI 2 3 4 1 17 2 1 4 6 3 5 18 ...
Page 103: ...2 1 19 2 1 4 6 3 5 20 XVII ...
Page 104: ...8 7 9 10 21 1 2 3 5 6 XVIII XVIII 4 ...
Page 105: ...XIX 1 2 3 1 3 2 B A 22 7 8 9 10 11 A 11 B 12 13 14 ...
Page 106: ...XX 23 24 1 2 3 4 5 6 ...
Page 108: ...XXII XXII 1 2 3 4 5 6 28 ...
Page 109: ...XXIII XXIII 29 30 1 2 3 4 5 6 ...