12 – English
EN
DIAGNOSTICS
This chapter covers the diagnostics for the UDL2 controller, with special reference to the 900 series firmware. We cover the meanings of the
display codes, which errors are displayed (their meanings and how to reset them) and the operation of the tSt program.
Code on
display
Programs for ramps with hinged lips (P11
– P12 – P13)
Programs for ramps with telescopic lips (P21 –
P23 – P25 – P31 – P32 – P33)
Note
P…
Valve setting. P1x = single-valve ramp
Valve setting. P2x, P3x = two/three valve ramp.
LF
Sensitivity of electric motor thermal cutout
Sensitivity of electric motor thermal cutout [min]
LE
N/A
Minimum telescopic lip extension time [s]
LA
N/A
Maximum telescopic lip extension time [s]
LN
N/A
Difference between telescopic lip retraction/extension
times [s]
During AUTORETURN, coincides
with status 00D
LR
The time employed by the ramp in travelling
from its maximum height to its standby
position [s]
The time employed by the ramp in travelling from its
maximum height to its standby position [s]
Coincides with status 00E
RB
Time available for industrial gate to close
before it is locked out [s]
Time available for industrial gate to close before it is
locked out [s]
If interlocking is implemented, this
coincides with status 00F
LC
The time employed by the ramp in travelling
from its minimum height to its standby position
[s]
The time employed by the ramp in travelling from its
minimum height to its standby position [s]
Coincides with status 00C
AR
Presence of AUTORETURN button
Not used
PC
Sensitivity of current measurement used to
detect the position of the lip while opening
Enables/disables the movement of the lip when it is
floating
In P31, one refers to status 00A
BU
Determination of ramp operating mode and
number of available buttons
Determination of ramp operating mode and number
of available buttons
LL
Not used
Length of telescopic lip
5 = 500mm
1 = 1000mm
001
Auto-test 1
Auto-test 1
002
Auto-test 2
Auto-test 2
003
Auto-test 3
Auto-test 3
004
Ramp waiting to be enabled
Ramp waiting to be enabled
Waiting to detect vehicle / chock
positioning / industrial door
opening
005
Ramp enabled
Ramp enabled
Ramp ready to move
006
Ramp UP
Ramp UP After 2s changes to status 007
007
Rotation of hinged lip
Ramp UP
008
N/A
Extension of telescopic lip
009
Lip fully open and Ramp DOWN
Ramp DOWN
010
Shelter / chock / vehicle detectors still active
Shelter / chock / vehicle detectors still active
011
Anti-collision function tripped
Anti-collision function tripped
Press AUTORETURN to quit
012
Incorrect floating position – the lip is properly
positioned on the vehicle
Incorrect floating position – the lip is properly
positioned on the vehicle
023
UDL2 controller first startup
UDL2 controller first startup
Press UP ARROW to continue
025
PEEP module programming
PEEP module programming
026
Operating mode and parameter programming
Operating mode and parameter programming
027
Display PEEP module programming (read only) Display PEEP module programming (read only)
00A
Floating position correct
Floating position correct
00C
Ramp UP after AUTORETURN pressed
Ramp UP after AUTORETURN pressed
00D
N/A
Retraction of telescopic lip
00E
Ramp DOWN after AUTORETURN pressed
Ramp DOWN after AUTORETURN pressed
00F
The ramp has reached the base (standby
position) / waiting for industrial gate to close
The ramp has reached the base (standby position) /
waiting for industrial gate to close
If interlocking implemented
SEr
Loading ramp full cycle counter
Loading ramp full cycle counter
Increments in status 00C
A01
RAM / ROM error
RAM / ROM error
A02
Procedure error
Procedure error
e.g. chock removed during
loading/unloading
A03
Electric motor power fault
Electric motor power fault
e.g. three-phase not available /
star/delta connection incorrect /
insulation damaged / short circuit
A04
Locked button error
Locked button error
See paragraph Protection – no
counter for this error
A06
Locked relay error
Locked relay error
See paragraph Protection – no
counter for this error
A07
Thermal cutout tripped
Thermal cutout tripped
See paragraph Protection – no
counter for this error
A08
Watchdog error
Watchdog error
See paragraph Protection – no
counter for this error
Summary of Contents for UDL 2
Page 2: ......
Page 27: ...English 11 EN UDL 2 BOARD OVERVIEW...
Page 41: ...Fran ais 11 FR VUE D ENSEMBLE CARTE UDL 2...
Page 69: ...Deutsch 11 DE PLATINE BERSICHT UDL 2...
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ...IS0146A01MM_06 10 2014 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com...