TECHNICAL SPECIFICATIONS

11

 

11 

TECHNICAL SPECIFICATIONS

All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). Nice S.p.A. 

reserves the right to apply modifications to the product at any time when deemed necessary, without altering 

its functions and intended use.

Table 14

TECHNICAL SPECIFICATIONS

Description

Technical specification

Mains power supply

Control unit MC824HHS: 230 V

a

 ±10% 50–60 Hz

Nominal power absorbed 

by the mains grid

200 W

Power draw of the 

control unit battery 

connector in “Stand-by 

all” mode

(including a receiver with 

SM-type connector)

below 100 mW

Warning light output 

[Note 1]

1 ELDC warning light

Electric lock output 

[Note 1]

1 x 12 V

a

 max 15 VA electric lock

Gate open indicator 

output [Note 1]

For 1 x 24 V maximum 4 W lamp (the output voltage may vary between –30% and +50% and can also control 

small relays)

BLUEBUS output

1 output with maximum load of 15 Bluebus units (maximum 6 pairs of MOFB or MOFOB phot 2 pairs of 

MOFB or MOFOB photocells addressed as opening d maximum 4 MOMB or MOTB control devices

STOP input

for normally closed or normally open contacts or for 8.2 kΩ fixed resistor contacts with self-learning (any 

variation from the memorised status triggers the “STOP” command)

SbS input

for normally open contacts (the closing of the contact triggers the “Step-by-Step” command)

OPEN input

for normally open contacts (the closing of the contact triggers the “OPEN” command)

CLOSE input

for normally open contacts (the closing of the contact causes the “CLOSE” command)

Radio connector

SM connector for SMXI, OXI and OXFIM receivers

Radio ANTENNA input

50 Ω for RG58-type cable or similar

Programmable functions

8 ON-OFF and 8 adjustable functions

Self-learning functions

Self-learning of the devices connected to the BlueBus output; self-learning of the type of device connected to 

the “STOP” terminal (NO, NC contact or 8.2 kΩ fixed resistor); self-learning of the gate leaf path and automatic 

calculation of the slowdown and partial opening points (which vary depending on the type of installation)

Operating temperature

-20°C ... +55°C

Use in highly acid, saline 

or potentially explosive 

atmosphere

NO

Protection rating

IP 54 with container intact

Dimensions (mm)

310 x 232 x H 122

Weight (kg)

4,1

Note 1

  The “Warning light”, “Electric lock” and “Gate open indicator” outputs can be programmed with other functions (see “

Table 6

” 

in the “

Level 1 programming (ON-OFF)

” paragraph) or through the Oview programmer (refer to the 

Connecting the IBT4N 

interface

” paragraph). The electrical characteristics of the output adapt to the programmed functions: warning light (12 V

c

max 21 W lamp) - electric lock (12 V

a

, max 15 VA) - other outputs (all types: 1 x 24 V lamp or relay

c

, –30% to +50%, 4 Wmax).

Summary of Contents for MC824HHS

Page 1: ...Nice MC824HHS Control unit EN Instructions and warnings for installation and use...

Page 2: ...care by avoiding crushing impacts falls or contact with liquids of any kind Do not place the product near sources of heat nor expose it to open flames All these actions can damage the product and caus...

Page 3: ...type radio receiver paragraph and an IBT4N type connector which through the IBT4N interface can be used to connect BusT4 devices such as the Oview programmer see the Connecting the IBT4N interface pa...

Page 4: ...ENTIFICATION AND OVERALL DIMENSIONS The overall dimensions and label A that allow for identifying the product are shown in Figure 2 232 mm 310 mm 122 mm A 2 3 4 TYPICAL INSTALLATION Figure 3 shows an...

Page 5: ...ectronic circuits 3 5 INSTALLING THE CONTROL UNIT a Secure the control unit to an unmovable vertical flat surface adequately protected against possible impacts The lower part of the control unit must...

Page 6: ...ositioned in sight of the automation If located in a concealed position it must be equipped with a system that prevents inadvertent or unauthorised reconnection of power to avoid potential hazards 4 2...

Page 7: ...open contacts NC normally closed contacts or devices with 8 2 k fixed resistor output such as sensitive edges can be connected to this input Each device connected to this input will be individually r...

Page 8: ...FOTO PHOTO External photocell h 50 activated during the closing phase stops and reverses the gate s movement FOTO II PHOTO II External photocell h 100 activated during the closing phase stops and reve...

Page 9: ...mode to be assigned to the motor see Table 4 Close Open SbS Stop Bluebus 1 2 3 4 5 6 7 8 9 10 11 12 A 13 m The motor selector must be set before activating the mechanical stop learning function m Any...

Page 10: ...trolled by M2 press f or h to stop the learning phase At this point reverse the connections of motors M1 and M2 on the terminals on the control unit and those of the respective encoders Then repeat th...

Page 11: ...button is released LED L7 will start flashing 9 LED L7 flashes position 1 of M1 to command and move motor 1 to position 1 Figure 14 press and hold the f or h button Once the position is reached relea...

Page 12: ...ether the leaves can be opened and closed with a force below 390 N 3 lock the motors as described in the respective instruction manual 4 using the control devices transmitter control button key select...

Page 13: ...ction short flash OFF long flash ON 5 wait 10 seconds maximum time to exit the programming mode l To set other functions to ON or OFF while the procedure is running repeat points 2 and 3 during the ph...

Page 14: ...10 seconds to press the buttons consecutively during the programming procedure after which time the procedure terminates automatically and memorises the changes made up to then To perform Level 2 pro...

Page 15: ...of the movement namely the opening of the gate leaves instead the Close command does not cause any effect If the sent command remains for more than 2 seconds a Stop command is executed L6 STEP BY STEP...

Page 16: ...nsmitter or key selector etc If everything functions properly the gate will move normally otherwise proceed with point 2 2 within 3 seconds press the control again and hold it down 3 after roughly 2 s...

Page 17: ...e cause and increase the motor force if necessary 4 short red flashes 1 second pause 4 short red flashes Intervention of the STOP input At the start of the manoeuvre or during the movement itself the...

Page 18: ...blown verify the cause and replace it with one having the same characteristics Green LED always on Serious anomaly There is a serious problem try disconnecting the power supply to the control unit an...

Page 19: ...ton to shift flashing of the LED to L8 Anomaly list parameter 4 keep the g button pressed down it must be kept pressed throughout phases 5 and 6 5 wait roughly 3 seconds after which LED L1 correspondi...

Page 20: ...mation Unlock or only from Oview the following commands Unlock and close and Unlock and open 12 Lock automation Triggers the stoppage of the manoeuvre and locks the automation the control unit will no...

Page 21: ...CT MAINTENANCE Being an electronic part the control unit does not require any special maintenance Nonetheless the system should be regularly checked to ensure that it works efficiently at least every...

Page 22: ...command SbS input for normally open contacts the closing of the contact triggers the Step by Step command OPEN input for normally open contacts the closing of the contact triggers the OPEN command CLO...

Page 23: ...according to the requirements envisaged for partly completed machinery Annex II part 1 section B Directive 2006 42 EC of the EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 related to machinery and am...

Page 24: ...24 ENGLISH NOTES...

Page 25: ...ystem or the programming and adjustment parameters of the control unit your installer is exclusively responsible for these operations Failure or power outage while waiting for your installer to interv...

Page 26: ...26 ENGLISH NOTES...

Page 27: ...ENGLISH 27 NOTES...

Page 28: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IDV0779A00EN_27 11 2020...

Reviews: