20
– ENGLISH
” show the “Receiver outputs” and the
“Control unit inputs” associated with each.
Table 12
SMXI / SMXIS OR OXI / OXIFM / OXIT / OXITFM IN MODE 1 OR
MODE 2
Receiver output
Control unit input
Output No. 1
“SbS” (Step-by-Step) command
Output No. 2
“Partial opening 1” command
Output No. 3
“Open” command
Output No. 4
“Close” command
Table 13
OXI / OXIFM /OXIT / OXITFM IN MODE 2 EXTENDED
No.
Command
Description
1
Step-by-Step
“SbS” (Step-by-Step) command
2
Partial opening 1
“Partial opening 1” command
3
Open
“Open” command
4
Close
“Close” command
5
Stop
Stops the manoeuvre
6
Condominium
Step-by-Step
Command in condominium mode
7
High priority Step-
by-Step
Commands also with the automation
locked or the commands enabled
8
Partial open 2
Partial opening (the M2 gate leaf
opens to 1/2 the full length)
9
Partial open 3
Partial open (the two gate leaves open
to 1/2 the full length)
10
Opens and locks
the automation
Triggers an opening manoeuvre
and, once this terminates, locks the
automation; the control unit will not
accept any command other than “High
priority Step-by-Step” and automation
“Unlock”, or (only from Oview) the
following commands: “Unlock and
close” and “Unlock and open”
11
Closes and locks
the automation
Triggers a closing manoeuvre and,
once this terminates, locks the
automation; the control unit will not
accept any command other than “High
priority Step-by-Step” and automation
“Unlock”, or (only from Oview) the
following commands: “Unlock and
close” and “Unlock and open”
12
Lock automation
Triggers the stoppage of the
manoeuvre and locks the automation;
the control unit will not accept any
command other than “High priority
Step-by-Step” and automation
“Unlock”, or (only from Oview) the
following commands: “Unlock and
close” and “Unlock and open”
13
Release
automation
Triggers unlocking of the automation
and restores normal operation
14
On Timer
Courtesy light
The courtesy light output switches on
with timer-based switching off
15
On-Off
Courtesy light
The courtesy light output switches on
and off in Step-by-step mode
l
For further information, consult the specific manual
of the receiver.
8.2 CONNECTING THE IBT4N INTERFACE
The control unit is equipped with a “IBT4N”-type connector for the
IBT4N interface, which allows for connecting all devices equipped
with BusT4 interface, such as, for example, Oview programmers
and the IT4WIFI Wi-Fi interface.
The Oview programmer allows for comprehensively and rapidly
managing the installation, maintenance and diagnosis of the entire
automated system.
f
Before connecting the interface, disconnect the
power supply to the control unit.
To install the interface (“
Figure
”):
1.
remove the cover of the control unit’s containment box
2.
fit the interface (
A
) into the appropriate slot (
B
) on the control
unit board
3.
insert the cable (
C
) in the appropriate slot (
D
) on the interface
C
D
B
A
25
At this stage, the control unit can be powered again.
l
For further information, consult the specific manuals
of the connected devices.
Summary of Contents for MC824HHS
Page 1: ...Nice MC824HHS Control unit EN Instructions and warnings for installation and use...
Page 24: ...24 ENGLISH NOTES...
Page 26: ...26 ENGLISH NOTES...
Page 27: ...ENGLISH 27 NOTES...