7.4 - Diagnostics
Some devices are able to emit signals that serve to recognise their state of
operation or possible faults.
7.4.1 - Signals of control unit
The LEDs of the terminals and the keys on the control unit emit special signals
both to indicate normal operation and possible faults. Tables
12
and
13
describe the cause and solution for each type of signal.
E
TABLE 12 - Terminal LEDs on control unit
Led Bluebus
Cause
Solution
Off
Fault
Check for presence of the power supply; check that the fuses are not
blown; in this case, identify the cause of the fault and then replace with
versions with the same specifications.
On
Serious fault
This indicates a serious fault; try switching off the control unit for a few
seconds; if the condition persists there is a fault and the electronic
board needs to be replaced.
1 flash per second
All OK
Normal operation of control unit.
2 quick flashesi
Input status variation
A variation to the status of the inputs SS, STOP, OPEN, CLOSE,
activation of the photocells, or when the radio transmitter is used,
is normal.
Series of flashes separated by
Various
This is the same signal of 1 second as on the flashing light
(See table 15).
Led STOP
Cause
Solution
Off
STOP input activation
Check the device connected to the STOP input
On
All OK
STOP input active
Led PP
Cause
Solution
Off
All OK
S.S. Input not active
On
S.S. input activation
Normal if the device connected to the S.S. input is active
Led OPEN
Cause
Solution
Off
All OK
OPEN input not active
On
OPEN input activation
Normal if the device connected to the OPEN input is active
Led CLOSE
Cause
Solution
Off
All OK
CLOSE input not active
On
CLOSE input activation
Normal if the device connected to the CLOSE input is active
FC1 limit switch LED
Cause
Solution
Off
Limit switch activation
- If the parameter “Standard motor rotation direction” is set, the pole
is in the total closing position.
- If the parameter “Inverted motor rotation direction” is set, the pole is
in the total opening position.
On
Limit switch not activated
- If the parameter “Standard motor rotation direction” is set, the pole
is in a position other than the total closing position.
- If the parameter “Inverted motor rotation direction” is set, the pole is
in a position other than the total opening position.
FC2 limit switch LED
Cause
Solution
Off
Limit switch activation
- If the parameter “Standard motor rotation direction” is set, the pole
is in the total opening position.
- If the parameter “Inverted motor rotation direction” is set, the pole
is in the total closing position.
On
Limit switch not activated
- If the parameter “Standard motor rotation direction” is set, the pole
is in a position other than the total opening position.
- If the parameter “Inverted motor rotation direction” is set, the pole is
in a position other than the total closing position.
Led encoder
Cause
Solution
Off
The magnet is in front of the sensor
If there is no manoeuvre in progress it is normal, otherwise there is a
fault in the encoder or the cable is not connected properly
On
The magnet is not in front of the sensor
If there is no manoeuvre in progress it is normal, otherwise there is
a fault in the encoder or the cable is not connected properly
Flashing light
Manoeuvre in progress
All OK if the manoeuvre is in progress; the flashing is proportional to
the speed
Note – During the execution of the manoeuvre, the flashing speed
could appear as LED on.
Summary of Contents for M3BAR
Page 2: ......
Page 26: ......
Page 30: ...II 4 3 b a c d g h f e c a b...
Page 31: ...III 5 6 MBAR a c d b...
Page 32: ...IV 90 8 9 MBAR a b c a b 7 a b...
Page 33: ...V 180 10 11 LBAR c a a b...
Page 34: ...VI 13 14 12 LBAR c a b...
Page 35: ...VII 15 16 18 17...
Page 36: ...VIII 19 20 21 23 22...
Page 37: ...IX 24 26 25 28 1 cm 27 29...
Page 38: ...X 33 34 30 31 32 c a b c a b...
Page 39: ...XI 35 36 37 45 38 a b a b c...
Page 41: ...XIII 42 43 44 STOP 45 46 LIGHT 47...
Page 42: ...XIV 48 49 50 a b c...
Page 43: ...XV 51 52 a b...
Page 44: ...XVI 53 a b c d e f g...
Page 46: ...XVIII F1 F1 F2 F2 55...
Page 47: ......
Page 48: ...ISTML BARR01 4865_07 10 2011 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com...