Menu 7.2 - logging
logging 7.2
activated
interval
sec
5
floor drying logging activated
Setting range: 1 s – 60 min
Factory setting range: 5 s
Here you can choose how current measurement values from
VVM 310 should be saved onto a log file on the USB memory.
1.
Set the desired interval between loggings.
2. Tick “activated".
3. The present values from VVM 310 are saved in a file in
the USB memory at the set interval until “activated" is
unticked.
Caution
Untick "activated" before removing the USB
memory.
Logging floor drying
Here you can save a floor drying log on the USB memory
and in this way see when the concrete slab reached the
correct temperature.
•
Make sure that "floor drying function" is activated in menu
5.9.
•
Select "logging floor drying activated".
•
A log file is now created, where the temperature and the
immersion heater output can be read off. Logging contin-
ues until "logging floor drying activated" is deselected or
until "floor drying function" is stopped.
Caution
Deselect "logging floor drying activated" before
you remove the USB memory.
Menu 7.3 - manage settings
manage settings 7.3
save settings
recover settings
Here you can manage (save as or retrieve from) all the menu
settings (user and service menus) in VVM 310 with a USB
memory.
Via "save settings" you save the menu settings to the USB
memory in order to restore them later or to copy the settings
to another VVM 310.
Caution
When you save the menu settings to the USB
memory you replace any previously saved settings
on the USB memory.
Via "recover settings" you reset all menu settings from the
USB memory.
Caution
Reset of the menu settings from the USB memory
cannot be undone.
53
Chapter 9 | Service
NIBE VVM 310