Energy meter (Electricity meter)
The energy meter(s) is used to send pulse signals every time
a certain amount of energy has been consumed.
energy per pulse: Here you set the amount of energy to
which each pulse will correspond.
pulses per kWh: Here you set the number of pulses per kWh
that are sent to VVM 310.
MENU 5.4 - SOFT IN/OUTPUTS
Here, you can select which input/output on the input board
(AA3) the external contact function (page 24) will be con-
nected to.
Selectable inputs on terminal block AUX 1-5 (AA3-X6:9-18)
and output AA3-X7 on the input board.
MENU 5.5 - FACTORY SETTING SERVICE
All settings can be reset (including settings available to the
user) to default values here.
Caution
When resetting, the start guide is displayed the
next time the indoor module is restarted.
MENU 5.6 - FORCED CONTROL
You can force control the different components in the indoor
module and any connected accessories here.
NOTE
Forced control is only intended to be used for
troubleshooting purposes. Using the function in
any other way may cause damage to the compon-
ents in your climate system.
MENU 5.7 - START GUIDE
When the indoor module is started for the first time the start
guide starts automatically. Start it manually here.
See page 30 for more information about the start guide.
MENU 5.8 - QUICK START
It is possible to start the compressor from here.
Caution
There must be a heating, cooling or hot water de-
mand to start the compressor.
NOTE
Do not quick start the compressor too many times
over a short period of time, as this could damage
the compressor and its surrounding equipment.
MENU 5.9 - FLOOR DRYING FUNCTION
length of period 1 – 7
Setting range: 0 – 30 days
Factory setting, period 1 – 3, 5 – 7: 2 days
Factory setting, period 4: 3 days
temp. period 1 – 7
Setting range: 15 – 70 °C
Default value:
20 °C
temp. period 1
30 °C
temp. period 2
40 °C
temp. period 3
45 C
temp. period 4
40 °C
temp. period 5
30 °C
temp. period 6
20 °C
temp. period 7
Set the function for under floor drying here.
You can set up to seven time periods with different calcu-
lated supply temperatures. If fewer than seven periods are
to be used, set the remaining periods to 0 days.
Mark the active window to activate the underfloor drying
function. A counter at the bottom shows the number of days
the function has been active.
NOTE
During under floor drying, the heating medium
pump in 100% runs, regardless of the setting in
menu 5.1.10.
TIP
If operating mode "add. heat only" is to be used,
select it in menu 4.2.
TIP
It is possible to save a floor drying log that shows
when the concrete slab has reached the correct
temperature. See section "Logging floor drying"
on page 53.
MENU 5.10 - CHANGE LOG
Read off any previous changes to the control system here.
The date, time, ID no. (unique to particular setting) and the
new set value are shown for every change.
Caution
The change log is saved at restart and remains
unchanged after factory setting.
49
Chapter 8 | Control – Menus