MENU 5.3.14 - F135
charge pump speed
Setting range: 1 – 100 %
Factory setting: 70 %
hot water at cooling
Setting range: on/off
Factory setting: off
Here you can set the charge pump speed for F135. You can
also choose whether you want to be able to charge hot water
with F135 at the same time as the outdoor module produces
cooling.
Caution
It is necessary for “active cooling 4 pipe” to be se-
lected in either “accessories” or “soft in/outputs”
to enable activation of “hot water during cooling”.
The heat pump must also be activated for cooling
operation.
MENU 5.3.16 - HUMIDITY SENSOR
climate system 1 HTS
Setting range: 1–4
Default value: 1
limit RH in the room, syst.
Setting range: on/off
Factory setting: off
prevent condensation, syst.
Setting range: on/off
Factory setting: off
limit RH in the room, syst.
Setting range: on/off
Factory setting: off
Up to four humidity sensors (HTS 40) can be installed.
Here you select whether your system(s) is/are to limit the
relative humidity level (RH) during heating or cooling opera-
tion.
You can also choose to limit min. cooling supply and calcu-
lated cooling supply to prevent condensation on pipes and
components in the cooling system.
See the Installer Manual for HTS 40 for function description.
MENU 5.3.18 - POOL
Here you select which pump to use in the system.
MENU 5.3.19 - ACTIVE COOLING 4 PIPE
Here you select which pump to use in the system.
MENU 5.3.21 - FLOW SENSOR / ENERGY METER
Supply temperature sensor
set mode
Setting range: EMK150 / EMK300/310 / EMK500
Factory setting: EMK150
energy per pulse
Setting range: 0 – 10000 Wh
Factory setting: 1000 Wh
pulses per kWh
Setting range: 1 – 10000
Factory setting: 500
Energy meter
set mode
Setting range: energy per pulse / pulses per kWh
Default value: energy per pulse
energy per pulse
Setting range: 0 – 10000 Wh
Factory setting: 1000 Wh
pulses per kWh
Setting range: 1 – 10000
Factory setting: 500
Up to two flow sensors (EMK) / energy meters can be con-
nected on the input board AA3, terminal block X22 and X23.
Select these in menu 5.2.4 - accessories.
Flow sensor (Energy measurement kit EMK)
A flow sensor (EMK) is used to measure the amount of en-
ergy produced and supplied by the heating installation for
hot water and heating in the building.
The function of the flow sensor is to measure flow and
temperature differences in the charge circuit. The value is
presented in the display on a compatible product.
Starting from software version 9085 , you can select the
flow sensor (EMK) you have connected in the system.
energy per pulse: Here you set the amount of energy to
which each pulse will correspond.
pulses per kWh: Here you set the number of pulses per kWh
that are sent to VVM 310.
Caution
The software in VVM 310 must be software version
9085 or later. Visit
and click on the
"Software" tab to download the latest software to
your installation.
NIBE VVM 310
Chapter 8 | Control – Menus