Control
General
All the most common settings are made from the panel
as well as control computer instructions such as comfort
temperature etc. In order for the installation to be used
optimally, certain default settings must have been made
and the installation carried out according to the relevant
instructions.
Start page
33.3
12:05
05
12:0
Boiler status
Week day
Hot water program
Time
Set boiler temp.
Boiler temp.
Processor temp.
Monitoring status
Heating program
Number unacknowledged
alarms
Burner program
TURNED OFF
Th
OFF
This is the menu that appears when PELLUX 100 is in its
normal/start position. The menu displays boiler status, set
temperature for the boiler and its current temperature. It
is also possible to see the date, time, whether the control
computer is being used or not, the running heating pro-
gram, the number of alarms as well as the processor tem-
perature.
Boiler status
Boiler status states what the boiler is doing right now.
Explanation
Status
Burner OFF and boiler monitoring are not
running.
OFF
Cleaning the boiler.
Cleaning
Settings of fuel volume for firing up, start
of the firing up sequence and fans.
Firing up
When the fuel has been ignited and a
flame can be detected, the fuel volume is
increased until the correct amount and
speed is reached.
Starting
The burner operates at 30 to 50 % power.
Power 1
The burner operates at a preset value
between 50 and 100 % power.
Power 2
The burner operates at a level adjusted by
the control computer between 30 and
100 % power.
Modulation type
Extinguishes the fire and controls the fans
until the flames have died down com-
pletely.
Burning off
The burner does not operate when the
boiler set temperature has been reached.
Stop
Control computer
The boiler is controlled by a computer that ensures that
all component parts work in the most efficient way for the
relevant operation.
The control computer controls and monitors heating and
hot water production and provides information about set
control conditions. In the event of a malfunction, an alarm
and warnings are transmitted to the display to keep the
user informed about the conditions at all time.
The control computer controls the boiler in a way that
prevents damage to the installation.
PELLUX 100
6
For Home Owners
Front panel