WARNING ! THIS APPLIANCE CLASS 1 APPARATUS AND MUST BE EATHED.
The green and yellow wire of the mains cord must always be connected to an
installation safety earth or ground. The earth is essential for personal safety as well as
the correct operation of the system, and is internally connected to all exposed metal
surfaces. Additional recommendation for interconnection to other equipment can be
found in the “Analogue TDcontroller Setting-Up Advice” section.
8.3 Analogue TDcontroller Setting-Up Advice
8.3.1 Mains Power
NEXO TDcontrollers don’t provide a mean to switch off the unit from the front panel. As they are
intended to be rack mounted the back panel is not accessible during use. Therefore it is left to the user
to provide a disconnection mean readily operable.
8.3.2 Voltage setting
NEXO TDcontrollers use a switch mode power supply (SMPS). This SMPS accepts universal AC power
input voltages in the range 90V to 264V, and requires no manual adjustment for voltages in this range.
8.3.3 Mounting the TDcontroller in a rack (Grounding, shielding & safety issues)
The TDcontroller is intended for rack mounting. The only accessible part during use shall be the front
panel of the TDcontroller. Any space above or under the TDcontroller shall be obstructed with a blank
panel.
The rack is a free grounding and shielding structure and it provides extra shielding. Therefore, it is
desirable that the screws used to fix the TDcontroller in the frame or rack provide an electrical contact
between the chassis of the TDcontroller and the rack.
The primary reason for grounding is safety. Conformance to the applicable requirements of the
authorities having jurisdiction is, of course, mandatory. However, grounding also has an impact on
electromagnetic compatibility. From the EMC point of view, it is desirable to have a low impedance
ground network, as a current flowing in the ground network will then produce low voltage in the network.
A low impedance network can be obtained using a multipoint ground scheme, with as many closed
ground loops as is economically possible.
8.3.4 Fuse
The fuse provided in the unit will not blow during normal operation. If the fuse blows the
TDcontroller has malfunctioned. This fuse must only be changed by NEXO certified
service personnel. In any case do not replace the fuse with a non-certified NEXO fuse, as
this will invalidate the NEXO warranty.
Summary of Contents for PS Series
Page 17: ...CONNECTION DIAGRAMS Page 17 82 5 CONNECTION DIAGRAMS 5 1 PS8 LS400 with PS8 TDController ...
Page 18: ...Page 18 82 CONNECTION DIAGRAMS 5 2 PS8 LS400 with NXAMP4x1 ...
Page 19: ...CONNECTION DIAGRAMS Page 19 82 5 3 PS8 LS400 with NXAMP4x4 ...
Page 20: ...Page 20 82 CONNECTION DIAGRAMS 5 4 PS10 LS600 with PS10 TDController ...
Page 21: ...CONNECTION DIAGRAMS Page 21 82 5 5 PS10 LS600 with NXAMP4x1 ...
Page 22: ...Page 22 82 CONNECTION DIAGRAMS 5 6 PS10 LS600 with NXAMP4x4 ...
Page 23: ...CONNECTION DIAGRAMS Page 23 82 5 7 PS15 Passive RS15 Omni with PS15 TDController ...
Page 24: ...Page 24 82 CONNECTION DIAGRAMS 5 8 PS15 Passive RS15 Omni with NXAMP4x1 ...
Page 25: ...CONNECTION DIAGRAMS Page 25 82 5 9 PS15 Passive RS15 Omni with NXAMP4x4 ...
Page 26: ...Page 26 82 CONNECTION DIAGRAMS 5 10 PS15 Active with NXAMP4x4 ...
Page 56: ...Page 56 82 TECHNICAL SPECIFICATIONS 9 1 2 Dimensions ...
Page 59: ...TECHNICAL SPECIFICATIONS Page 59 82 9 2 2 Dimensions ...
Page 62: ...Page 62 82 TECHNICAL SPECIFICATIONS 9 3 2 Dimensions ...
Page 66: ...Page 66 82 TECHNICAL SPECIFICATIONS 9 5 2 U Bracket for PS10R2 VNT SSBRK10 Parts Dimensions ...
Page 67: ...TECHNICAL SPECIFICATIONS Page 67 82 9 5 3 U Bracket for PS15R2 VNT SSBRK15 Parts Dimensions ...
Page 73: ...TECHNICAL SPECIFICATIONS Page 73 82 9 6 2 PS10R2 U Bracket VNI UBRK10 Parts Dimensions ...
Page 74: ...Page 74 82 TECHNICAL SPECIFICATIONS 9 6 3 PS15R2 U Bracket VNI UBRK12 Parts Dimensions ...