Adjust High Flame Setting Screw
2. Use a flat-blade screwdriver to turn the high flame
setscrew counterclockwise approximate 90 degree.
3. Lift the searing side burner out of the grill.
4. Use 6 mm socket wrench or 6 mm nut driver to remove the
orifice. Replace with the Natural gas orifice.
IMPORTANT
: Check that the orifice is properly installed inside of the
valve.
5. Reinstall the searing side burner Make sure that the igniter is out
of the way to allow proper positioning of burner. Use Phillips
screwdriver to attach the mounting screws.
6. Use Phillips screwdriver to reattach the igniter and searing side
burner plate.
7. Reinstall searing side burner cover. Use Phillips screwdriver to
attach mounting screws.
8. Open the manual shutoff valve in the gas supply line. The valve is
open when the handle is parallel to the gas pipe.
9. Test all connections using an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct
any leak found.
When converting from LP to Natural gas, you will need to adjust
the high flame setting screw for ideal burner flame height.
1. Remove each control knob for the main burners and side burner
3. Check that burner operates at the new high flame setting.
It may be necessary to adjust the screw setting slightly more to
get the ideal burner flame height.
orifice
orifice
19
A. Closed valve
B. Open valve
In the last page of the Use and Care Guide, writer
“
Converted
to Natural Gas.
”
Also record the conversion date and the
technician/company that performed the conversion.
Note:
Place LP gas parts in plastic parts bag for future use and
keep with pack containing literature.
1. The appliance nameplate is located inside the grill cabinet
on the left
–
hand cabinet side. With a permanent marker,
check the box next to
“
Natural gas
”
and mark through
“
LP-
Propane.
”
Record Conversion