3.3.3
SERIAL PORT CONFIGURATION
3.3.4
VISCA PROTOCOL
P
ART
1
-
C
AMERA
R
ETURN
C
OMMANDS
Z = camera 8
Error Messages
Command Packet Note
Syntax Error
z0 60 02 FF
Returned when the command format is different or when a
command with illegal command parameters is accepted
Command Not
Executable
z0 61 41 FF
Returned when a command cannot be executed due to current
conditions. For example, when commands controlling the focus
manually are received during auto focus.
P
ART
2
–
C
AMERA
C
ONTROL
C
OMMANDS
Command type
Function
Command
Address Set
Broadcast
88 30 01
FF
Address setting
IF Clear
Broadcast
88 01 00
01 FF
I/F Clear
Command Cancel
8x 21 FF
CAM Power
On
8x 01 04
00 02 FF
Power ON / OFF
Off
8x 01 04
00 03 FF
CAM Zoom
Stop
8x 01 04
07 00 FF
Tele (Standard)
8x 01 04
07 02 FF
Wide (Standard)
8x 01 04
07 03 FF
Parameter
Value
Parameter
Value
Baud rate
2400/4800/9600/115200 Stop Bit
1bit
Start Bit
1 bit
Check Bit
None
Date Bit
8 bit
Ack/Completion Message
Command Packet Note
ACK
z0 41 FF
Returned when the command is accepted
Completion
z0 51 FF
Returned when the command has been executed