Modem
Reference Manual for EL470 IP Satellite Modem
Command
MoSymRate
Symbol rate
Symbol rate
Location
/Modem/Control/Modulation/Main
Description
Configuration of the symbol rate. The actual range depends on installed
hardware and software capability.
RMCP
Command
TRs
Access
Normal user : RW
Expert user : RW
SNMP
Table
ntcDevsMod01ModulatorEntry
Command
ntcDevsMod01MoSymRate
OID
1.3.6.1.4.1.5835.3.1.3.1.32.1.1
Values
GUI Unit
Mbaud
Cmd Unit
Factory Default (CU)
baud
6.000.000
Expert Range (CU)
50000 .. 68000000
Command
MoOpOutputFreq
Operational output
frequency
Output frequency
Location
/Modem/Control/Modulation/Main
Description
Configuration of the operational output frequency in case of an active
L-band output.
RMCP
Command
OOF
Access
Normal user : RW
Expert user : RW
SNMP
Table
ntcDevsMod01ModulatorEntry
Command
ntcDevsMod01MoOpOutputFreq
OID
1.3.6.1.4.1.5835.3.1.3.1.38.1.1
Values
GUI Unit
MHz
Cmd Unit
Factory Default (CU)
Hz
1.450.000.000
Expert Range (CU)
-1e+38 .. 1e+38
Command
MoOutputLevel
Output level
Output level
Location
/Modem/Control/Modulation/Main
Description
Read out of the output level in dBm. The actual range is determined by the
gain of the converter (which depends on operating frequency) and the
gain of an optional amplifier.
Remark: The displayed level can be affected by introducing a level offset
(see
MoOLevelOffset
).
RMCP
Command
OOL
array : [1 ..
2]
Access
Normal user : RW
Expert user : RW
SNMP
Table
ntcDevsMod01ModulatorEntry
Command
ntcDevsMod01MoOutputLevel
OID
1.3.6.1.4.1.5835.3.1.3.1.29.1.1.[1 .. 2]
Values
GUI Unit
dBm
Cmd Unit
Factory Default (CU)
dBm
-15
Expert Range (CU)
-35 to +5
version 3.1