Modem
Reference Manual for EL470 IP Satellite Modem
Command
MoBufNonQosTimeLim
qos unaware eth-to-
mod queue size
qos unaware eth-to-m
Location
/Modem/Test/Interfaces
Description
Configuration of the queue length in milliseconds for Ethernet packets that
travel from the Ethernet interface board to the modulator board. This small
queue is not quality of service aware. It should be small enough, to avoid
non-quality of service aware queuing. It should be large enough, to avoid
buffer underflow: buffer underflow would reduce the throughput of the
system.
RMCP
Command
qub
Access
Normal user : no
access
Expert user : RW
SNMP
Table
ntcDevsMod01ModulatorEntry
Command
ntcDevsMod01MoBufNonQosTimeLim
OID
1.3.6.1.4.1.5835.3.1.3.1.105.1.1
Values
GUI Unit
mS
Cmd Unit
Factory Default (CU)
mS
5
Expert Range (CU)
0 .. 30000
/Modem/Test/Modulation
Command
IfBbbTxSig
Internal Baseband
Output to Modulator
Internal BB Output
Location
/Modem/Test/Modulation
Description
Configuration of the output signal to the internal modulator baseband
board connector.
Typically four possibilities exist:
•
By default the active external interface input signal is selected.
•
When an additional processing function is present (e.g. rate
adaptation), the output of the processing block can be selected.
•
For testing purposes a test generator signal can be routed to the
modulator.
•
The selection off, disables the output signal.
RMCP
Command
BTS
Access
Normal user : no access
Expert user : RW
Values
Factory Default
off
Enumeration
Value
OFF
Rx Sig
TG
Proc Signal
AIS
Buffer
0
1
2
3
4
5
version 3.1
236
SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS