29
It is
important
that the flue connection, any appliance baffles or throat plates and the
chimney are swept, cleaned, and inspected by an approved and registered chimney sweep
prior to lighting up after prolonged shutdown periods.
The installer may have fitted a permanent air supply vent into the room in which the stove
is installed to provide combustion and / or ventilation air. This air vent
must not
under any
circumstances be shut off or sealed.
Clearances to furniture, soft furnishings & combustible materials
Serious consideration
should be given to positioning of any furniture or soft furnishings
that could be adversely affected by heat. Newman Fireplaces Ltd recommend that any
furniture or soft furnishings or any combustible materials to be a
minimum of 2000 mm
away from the stove.
Never
use or store aerosol sprays or any other combustible products
in the vicinity of the stove when it is in operation or whenever the stove is hot. The stove
will remain hot for some time even after the fire is extinguished.
Never
place laundry near to the stove.
DO NOT
place photographs, TV's, paintings, porcelain, etc or other combustible items on
the wall or near to the appliance. Exposure to hot temperatures can be dangerous and
cause damage.
Never
over fire or use incorrect fuel to the stove as this can be dangerous and cause
damage to the stove and invalidate the stove warranty.
This appliance has been tested at a nominal heat output to the requirements of EN
13240:2001 for intermittent operation, it is
VERY IMPORTANT
you
DO NOT
exceed the
maximum fuel loads and operation of the stove is followed as the instructions.
Only use
this appliance for domestic property heating in accordance with these
instructions.
This stove
is not suitable
for any type of water vessel.
Your
home building insurance
company may require you to inform them that a new
heating appliance has been installed on your property, so it is strongly advised to check
with your insurance provider. Check that your cover is still valid after installing the
appliance and check with them if all chimney sweeping, cleaning and inspections
certificates are required to be kept together with the approved stove installer, installation,
and service maintenance records.
This stove should be serviced at
least annually
by a suitably qualified and registered stove
installer.
Extra fuel
must not
be stored on, below or next to the stove.
Never
use or store aerosol sprays or any other combustible products in the vicinity of the
stove when it is in operation or whenever the stove is hot. The stove will remain hot for
some time even after the fire is extinguished.
This stove contains consumable parts, and their replacement intervals can vary depending
on how the stove is operated and the fuel being used. Also, a heavy buildup of ashes on the
main grate will cause premature damage, see section 4.3.3
An approved Carbon Monoxide detector alarm conforming to the latest edition of BS EN
50291
must be
installed into the room the stove is installed. Installation and positioning