18
Operating Current
Table 4-3
T=25°C
Mode
State
Typical
Maximum
Unit
Working Current
RMS
1
VCC=5V
275
370
mA
PEAK
2
/
850
mA
Idle Current
RMS
1
150
180
mA
1. RMS indicates the RMS value of the current under the stable working state.
2. PEAK indicates the peak current the device reaches.
I/O Voltage
Table 4-4
GND
=0 V, T=25°C
Note: The VOH of SW_OUT determined by the pull-up voltage should not exceed 24V.
Parameter
Description
Condition
Minimum
Typical
Maximum
Unit
SW_IN
VIL
T=25°C
0
/
0.8
V
VIH
T=25°C
4.0
/
5.0
V
SW_OUT
VOL
T=25°C
0
/
0.4
V
VOH
T=25°C
/
/
24
V