Enter Setup
** Exit Setup
102
Formatter Command Type 6
When working with the Data Formatter, a virtual cursor is moved along your input data string. The following commands are
used to both move this cursor to different positions, and to select, replace, and insert data into the final output. For the hex
value of ASCII characters involved in the commands, refer to the
“ASCII Table”
in Appendix.
Send Commands
F1 Send all characters
Syntax=F1xx (xx: T
he insert character’s hex value)
Include in the output message all of the characters from the input message, starting from current cursor position, followed
by an insert character.
F2 Send a number of characters
Syntax=F2nnxx (nn: The numeric value (00-99) for the number of characters; xx: The insert character
’s hex value)
Include in the output message a number of characters followed by an insert character. Start from the current cursor position
and continue for
“nn” characters or through the last character in the input message, followed by character “xx.”
F2 Example: Send a number of characters
Send the first 10 characters from the barcode above, followed by a carriage return.
Command string:
F2100D
F2 is the “Send a number of characters” command
10 is the number of characters to send
0D is the hex value for a CR
The data is output as:
1234567890
<CR>
Summary of Contents for NLS-FM515 Series
Page 1: ...Fixed Mount Barcode Scanner NLS FM515 Series...
Page 3: ...Revision History Version Description Date V1 0 0 Initial release June 29 2022...
Page 10: ...Code ID Table V1 00 0 145 Symbology ID Number V1 00 0 146 ASCII Table 147 Unicode Key Maps 151...
Page 109: ...Enter Setup 99 Exit Setup Format_0 Format_1 Format_2 Format_3...
Page 146: ...136 Appendix Digit Barcodes 0 9 0 1 2 3 4 5...
Page 147: ...137 6 7 8 9...
Page 148: ...138 A F A B C D E F...
Page 161: ...151 Unicode Key Maps 104 Key U S Style Keyboard 105 Key European Style Keyboard...
Page 162: ......