Enter Setup
113
** Exit Setup
32 is the hex value for 2 (character in the string to be replaced)
33 is the hex value for 3 (character in the string to be replaced)
03 is the length of the replacement string
41 is the hex value for A (character in the replacement string)
42 is the hex value for B (character in the replacement string)
43 is the hex value for C (character in the replacement string)
F1 is the
“Send all characters” command
00 is the hex value for a NUL
The data is output as:
cd1ABCabcABCbc12abABC2
BA Example: Remove only the first occurrence of
“23”s in barcode data
If the barcode has a string of characters that the host application wants removed, you can use the BA command to replace
the string with NUL. In this example, you will remove the first occurrence of
“23” in the barcode above.
Command string:
BA0102323300F100
BA is the
“Replace a string with another” command
01 is the count of replacements to be made
02 is the length of the string to be replaced
32 is the hex value for 2 (character in the string to be replaced)
33 is the hex value for 3 (character in the string to be replaced)
00 is the length of the replacement string, 00 means to replace the string to be replaced with NUL
F1 is the
“Send all characters” command
00 is the hex value for a NUL
The data is output as:
cd1abc23bc12ab232
Summary of Contents for NLS-FM515 Series
Page 1: ...Fixed Mount Barcode Scanner NLS FM515 Series...
Page 3: ...Revision History Version Description Date V1 0 0 Initial release June 29 2022...
Page 10: ...Code ID Table V1 00 0 145 Symbology ID Number V1 00 0 146 ASCII Table 147 Unicode Key Maps 151...
Page 109: ...Enter Setup 99 Exit Setup Format_0 Format_1 Format_2 Format_3...
Page 146: ...136 Appendix Digit Barcodes 0 9 0 1 2 3 4 5...
Page 147: ...137 6 7 8 9...
Page 148: ...138 A F A B C D E F...
Page 161: ...151 Unicode Key Maps 104 Key U S Style Keyboard 105 Key European Style Keyboard...
Page 162: ......