© 2005 GE Security 

MAINST-ATS1197 

 

All rights reserved 

03/2005 

š

 

 

   

   

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ATS1197

Smart Card Reader with Keypad

™

RAS 2 = 

 

1 2 3 4 5

Address

TERM

RAS 1

1 2 3 4

RAS 5

1 2 3 4

RAS 9

1 2 3 4

RAS 13

1 2 3 4

RAS 2

1 2 3 4

RAS 6

1 2 3 4

RAS 10

1 2 3 4

RAS 14

1 2 3 4

RAS 3

1 2 3 4

RAS 7

1 2 3 4

RAS 11

1 2 3 4

RAS 15

1 2 3 4

RAS 4

1 2 3 4

RAS 8

1 2 3 4

RAS 12

1 2 3 4

RAS 16

1 2 3 4

Summary of Contents for ATS1197

Page 1: ...d Reader with Keypad RAS 2 1 2 3 4 5 Address TERM RAS 1 1 2 3 4 RAS 5 1 2 3 4 RAS 9 1 2 3 4 RAS 13 1 2 3 4 RAS 2 1 2 3 4 RAS 6 1 2 3 4 RAS 10 1 2 3 4 RAS 14 1 2 3 4 RAS 3 1 2 3 4 RAS 7 1 2 3 4 RAS 11 1 2 3 4 RAS 15 1 2 3 4 RAS 4 1 2 3 4 RAS 8 1 2 3 4 RAS 12 1 2 3 4 RAS 16 1 2 3 4 ...

Page 2: ...or links Note ON is indicated as black down Example RAS 2 On Off Off Off CONNECTIONS Colour Application Red 12 V nominal 8 5 to 14 VDC supply The RAS can be powered using the bus and power from the control panel if the distance between the RAS and the control panel does not exceed 100 m 328 feet Otherwise the RAS can be powered by AUX PWR from a DGP or by an auxiliary power supply Black 0V DC supp...

Page 3: ...erational or the bus is faulty usually cabling Tx The red Tx LED flashes to indicate the RAS is replying to polling from the control panel If the Rx LED flashes but the Tx LED does not the RAS is not programmed to be polled in the control panel or is addressed incorrectly CONFIGURING THE ATS 1197 RAS To Configure the RAS Press 19 ENTER followed by 3 ENTER Type the requred RAS address 2 16 followed...

Page 4: ...abled RTE Only This option requires a simple push button to be connected to the yellow wire A press of the button will release the door lock relay Used for a quick exit from an Area enabled by default RTE Arm Disarm Do not use Menu 11 Factory Defaults This option returns all RAS settings to the factory default condition Menu 13 Last Card This option displays the number of the last card badged on t...

Page 5: ...emperatura di funzionamento Temperatura de operação Driftstemperatur 40 to 50 C 40 to 122 F Umidità Humidade Fuktighet 95 non condensing Datos técnicos Tekniska data Technische Daten Tensión de alimentación Matningsspänning Versorgungsspannung 8 5 14 VDC Max Corriente máxima de funcionamiento Maximal driftsström Maximale Stromaufnahme 110mA 13 8 VDC Corriente normal de funcionamiento todas las áre...

Page 6: ...6 ...

Page 7: ...7 ...

Page 8: ...horse Road Mitcham 3132 Australia EMC Technologies Pty Ltd 57 Assembly Drive Tullamarine 3043 Victoria Australia Test report reference M040929 1 IEC 60950 Test Report For ATS1197 M040929 2 APPLIED STANDARDS EN50130 4 1995 A1 1995 EN60950 2000 EN300330 2 v1 1 1 06 2001 Equipment class identifier RF products falling under the scope of R TTE Not Applicable X None class 1 product class 2 product Means...