background image

 

                                               Part No. 803171 Issued 3-28-13 Rev 011515 

 

 

  Taste Calibration For Postmix Beverage Dispenser With Low Pressure Faucet 

 
 
 

 

 

                

    

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

Remove Top Cover. 

Remove Product And 

Hang Over Sides Of 

Dispenser. 

Loosen Screw, Slide Access Panel 

Toward Front And Remove. 

After Access Panel Is Removed 

Adjustment Dials Are Accessible  

From The Top Side. 

Summary of Contents for 872B

Page 1: ...h the water A built in water pressure regulator ensures the proper amount of syrup is being mixed with the proper amount of water This built in pressure regulator is factory adjusted for a static pres...

Page 2: ...fitting on rear of dispenser Fitting may vary 4 Turn on the water source to the dispenser 5 Turn the yellow handle to the ON position to allow water to flow through the urn Product Loading 1 Open the...

Page 3: ...unit or when changing product Flush should be performed at least once a week Note Cleaning requires the use of a cleaning flush adapter An adapter may be purchased from Newco Enterprises Inc 320282 fo...

Page 4: ...nd close the faucet handle to relieve system of water 4 Wipe inside of faucet body with a mild dishwashing soap and hot water 5 Do the same to handle cap and seat cup 6 Reinstall assembly to faucet bo...

Page 5: ...tion with 200 ppm available chlorine can be made by adding oz 1 tablespoon of regular household bleach 6 sodium hypochlorite solution per gallon of water Do s and Don ts OPERATION 1 Do fully activate...

Page 6: ...ater only no product 1 Concentrate BIB empty 2 Product hose clogged 3 Product hose kinked 4 Check valve not seating 5 Adjustment screw in too far 1 Load new BIB 2 Clean product hose or replace 3 Check...

Page 7: ...n For Postmix Beverage Dispenser With Low Pressure Faucet Remove Top Cover Remove Product And Hang Over Sides Of Dispenser Loosen Screw Slide Access Panel Toward Front And Remove After Access Panel Is...

Page 8: ...l Counter Clockwise For Stronger Mixture Or Clockwise For Leaner Mixture Make small adjustments approximately 1 points or 1 8 turn at a time After Adjustments Are Made Replace Access Panel Tighten Scr...

Page 9: ...Part No 803171 Issued 3 28 13 Rev 011515 9...

Page 10: ...Part No 803171 Issued 3 28 13 Rev 011515 10...

Page 11: ...Part No 803171 Issued 3 28 13 Rev 011515 11 Additional Parts 14410 Black Plastic Cover Small 803197 Drip Tray S S Grid...

Page 12: ...dial plate after the dial knob is removed This area is now open for cleaning and troubleshooting When reassembling dial knob to shaft be sure that the white indicator is in the same position as befor...

Reviews: