Installation and Operation:

1. Remove cabinet cover. Install the short, white inner discharge tubes on the outlets of the eductors. They go over the

smaller barbed parts on the bottom of the eductors. These tubes must be in place for the eductors to function. The inner
discharge tube for the 14 LPM (yellow) eductor has a yellow flooding ring inside it. The inner discharge tube for the 4.0
LPM (grey) eductor has a grey flooding ring inside it. Install the end of the tube nearest the flooding ring on the eductor's
inner discharge  barb. 

To ensure the IDTs are on correctly,  the metal rings should be above the small barbs.

2. Drill holes for the three wall anchors with a 8mm drill bit, using the cabinet back as a template for correct spacing of the

mounting screws. Install mounting anchors, and then screws in top two anchors. Slide key holes in cabinet back over
screw heads, tighten screws, then install bottom screw. Do not mount more than 1.8 metres above the bottom of  the
concentrate container, nor below the highest concentrate level (never mount your concentrate higher than the
proportioner).

3. Select metering tips (up to 4) for the selector valve (see next two sections). Push each tip firmly into a separate hose

barb extending from the selector valve. A tip with no hole (clear plastic) can be used to block any valve port not being
used. (This may be used for dispensing water only.) Select and install a metering tip for the single product eductor (on
right hand side) in the same manner.

4. Cut tubing provided into separate supply tubes for each product to be dispensed (tubing allows for 2.1 m of tube per

product). Supply tubes should reach from hose barb on the selector valve body and eductor to bottom of concentrate
containers. Slide ceramic weights over one end of each tube and slide foot valves into the same ends of the tubes.

5. Slip open end of each supply tube through an opening in either side of the cabinet and push over a hose barb/metering

tip on the selector valve and on the eductor.

6. Place foot valve ends of supply tubes into concentrate containers. REMEMBER TO CHECK FOOT VALVE STRAINERS

PERIODICALLY FOR CLOGGING: CLEAN IF NECESSARY.

7. A short discharge tube is used with the 4 LPM eductor (selector valve); minimum tube length is 20 cm for correct

operation. A longer tube (1.2 m) is used with the 14 LPM eductor. Slide end of tube over inner discharge tube and onto
eductor discharge outlet. The hose hook supplied may be installed on the long tube to allow it to hang conveniently from
dispenser when not in use.

8. Replace cabinet cover. Push the sides in, behind the latch holes, to snap the cover in place. The two screws provided

may be installed in the holes in the cabinet sides to prevent easy removal of cover.

9. Connect water supply hose of at least 13 mm ID to water inlet swivel. (Minimum 1.7 bar pressure, 

with water running

,

is required for correct operation.) Connect opposite end of hose to water supply. Turn water supply on.

10. Purge air from the system by depressing the buttons briefly. There may be some water discharge from the eductor vents

until the air is purged.

11. Push button to start flow of desired water/concentrate solution, and hold until supply tube is primed (filled). Then push

the button whenever dispensing is desired, and release button to stop flow of solution. If you wish to be able to lock
the button in the "on" position: Clip or bend the two tabs behind the lower front  portion of the button. (See diagram
at right.) This allows the button to be fully depressed and allows it to latch in
the "on" position. 

To unlock, PULL THE BUTTON OUT.

12.

It is essential that the discharge hose is not obstructed. If discharge is
restricted, water will flow out of the eductor vents. Do not start to
operate the dispenser with liquid in the discharge tube.

AccuDose Series Proportioner Model 3876GBA-2

with HydroGap

 

Air Gap Eductors

Package Should Contain:

1. Proportioner unit.
2. Supply tubing : 6.4m total.
3. Foot valve assemblies & weights (5).
4. Discharge tube for each eductor.
5. Metering tip kits.
6. Mounting anchor kit.
7. Hook for 14 LPM discharge tube.
8. Instruction sheet.

Clip or
bend
these
tabs to
depress
button
into locked
position.

Summary of Contents for AccuDose 3876GBA-2

Page 1: ...n the selector valve and on the eductor 6 Placefootvalveendsofsupplytubesintoconcentratecontainers REMEMBERTOCHECKFOOTVALVESTRAINERS PERIODICALLYFORCLOGGING CLEANIFNECESSARY 7 A short discharge tube is used with the 4 LPM eductor selector valve minimum tube length is 20 cm for correct operation A longer tube 1 2 m is used with the 14 LPM eductor Slide end of tube over inner discharge tube and onto...

Page 2: ...etering tip size and product viscosity All that is required is to operate the primed dispenser for a minute or so and note two things the amount of dispensed solution and the amount of concentrate used in preparation of the solution dispensed The water to product ratio is then calculated as follows Dilution Ratio X 1 where X Amount of Mixed Solution Amount of Concentrate Drawn Amount of Concentrat...

Page 3: ...80723 Hose hook green 10080724 Hose hook light grey 10080725 Hose hook yellow Hose hooks are for 14 LPM discharge tubes 16 10080920 Selector valve replacement kit e Suction stub f O ring g selector valve assembly 17 690014 Metering tip kit 18 500870 Tubing 6mm x 2 1 m 19 509900 Weight 20 10076301 Foot valve Viton EPDM also available Order 10076302 NOT SHOWN 641750 Security screws for cabinet sides...

Page 4: ... hose barb ensure inner discharge tube innerdischargetube is installed and has flooding ring e Concentratecontainerempty e Replace with full container f Inlet hose barb not screwed f Tighten butdonotovertighten intoeductortightly g Clogged water inlet strainer g Disconnect inlet water line and clean strainer h Selector out of position h Assure selector is in position desired 3 Excess concentrate d...

Reviews: