background image

                                          Part No. 803171 Issued 3-28-13 Rev. 011515  

12 

DIAL REMOVAL  

 

Use 1.5mm hex wrench to remove dial knob. This wrench is supplied with 
the unit. IMPORTANT: When removing the dial knob note the position of 
the white indicator on the knob. Remove the dial plate after the dial knob is 
removed. This area is now open for cleaning and troubleshooting. 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

When reassembling dial knob to shaft be sure that the white indicator is in 
the same position as before. If factory orientation is lost turn the bare dial 
knob shaft clockwise until it stops and position the dial as shown above. 
Tighten setscrew. 

 

1.5 mm Hex Wrench #803201 

3mm x 5mm Setscrew #803200 

Dial Knob #803118 

Dial 
Plate

 

White 

Indicator 

Summary of Contents for 872B

Page 1: ...h the water A built in water pressure regulator ensures the proper amount of syrup is being mixed with the proper amount of water This built in pressure regulator is factory adjusted for a static pres...

Page 2: ...fitting on rear of dispenser Fitting may vary 4 Turn on the water source to the dispenser 5 Turn the yellow handle to the ON position to allow water to flow through the urn Product Loading 1 Open the...

Page 3: ...unit or when changing product Flush should be performed at least once a week Note Cleaning requires the use of a cleaning flush adapter An adapter may be purchased from Newco Enterprises Inc 320282 fo...

Page 4: ...nd close the faucet handle to relieve system of water 4 Wipe inside of faucet body with a mild dishwashing soap and hot water 5 Do the same to handle cap and seat cup 6 Reinstall assembly to faucet bo...

Page 5: ...tion with 200 ppm available chlorine can be made by adding oz 1 tablespoon of regular household bleach 6 sodium hypochlorite solution per gallon of water Do s and Don ts OPERATION 1 Do fully activate...

Page 6: ...ater only no product 1 Concentrate BIB empty 2 Product hose clogged 3 Product hose kinked 4 Check valve not seating 5 Adjustment screw in too far 1 Load new BIB 2 Clean product hose or replace 3 Check...

Page 7: ...n For Postmix Beverage Dispenser With Low Pressure Faucet Remove Top Cover Remove Product And Hang Over Sides Of Dispenser Loosen Screw Slide Access Panel Toward Front And Remove After Access Panel Is...

Page 8: ...l Counter Clockwise For Stronger Mixture Or Clockwise For Leaner Mixture Make small adjustments approximately 1 points or 1 8 turn at a time After Adjustments Are Made Replace Access Panel Tighten Scr...

Page 9: ...Part No 803171 Issued 3 28 13 Rev 011515 9...

Page 10: ...Part No 803171 Issued 3 28 13 Rev 011515 10...

Page 11: ...Part No 803171 Issued 3 28 13 Rev 011515 11 Additional Parts 14410 Black Plastic Cover Small 803197 Drip Tray S S Grid...

Page 12: ...dial plate after the dial knob is removed This area is now open for cleaning and troubleshooting When reassembling dial knob to shaft be sure that the white indicator is in the same position as befor...