Newco 872B User Manual Download Page 2

                                                                                       Part No. 803171 Issued 3-28-13   Rev 011515 

Installation 

1.  Carefully remove the dispenser from the 

shipping carton. 

2.  

Before attaching the waterline to the 
dispenser, flush the waterline to re- 
move any foreign particles that may 
be in the line.

 

NOTE:  

It is advisable to use a lime, scale, 

sediment, taste and odor purification char- 
coal water filter where water quality is a 
concern. 
3.  Connect waterline to inlet fitting on 

rear of dispenser. Fitting may vary. 

4.  Turn on the water source to the 

dispenser. 

5. Turn the yellow handle to the ON position   

to allow water to flow through the urn. 

 
 
                      

Product Loading 

1.  Open the BIB along the perforated edges. 

Pull out the dispensing spout.   

2.  Remove the cap from the spout. 
3.  Connect the QCD as shown to 

dispensing spout. Scholle fitting screws 
onto BIB. 

Note:  THE FITMENT MUST BE PUSHED 
ALL THE WAY OUT SO THAT  THE 
WORD “OUT” IS EXPOSED ON THE 
TOP OF THE FITMENT. 

 

 

 
 
 

4. Place the QCD into the neck of the 
    dispensing spout at the ridge as  
    shown on the illustration. 

 

 
 

 

 

 
 

 

Water 

On 

Water 

Off 

OUT 

RIDGE 

Summary of Contents for 872B

Page 1: ...h the water A built in water pressure regulator ensures the proper amount of syrup is being mixed with the proper amount of water This built in pressure regulator is factory adjusted for a static pres...

Page 2: ...fitting on rear of dispenser Fitting may vary 4 Turn on the water source to the dispenser 5 Turn the yellow handle to the ON position to allow water to flow through the urn Product Loading 1 Open the...

Page 3: ...unit or when changing product Flush should be performed at least once a week Note Cleaning requires the use of a cleaning flush adapter An adapter may be purchased from Newco Enterprises Inc 320282 fo...

Page 4: ...nd close the faucet handle to relieve system of water 4 Wipe inside of faucet body with a mild dishwashing soap and hot water 5 Do the same to handle cap and seat cup 6 Reinstall assembly to faucet bo...

Page 5: ...tion with 200 ppm available chlorine can be made by adding oz 1 tablespoon of regular household bleach 6 sodium hypochlorite solution per gallon of water Do s and Don ts OPERATION 1 Do fully activate...

Page 6: ...ater only no product 1 Concentrate BIB empty 2 Product hose clogged 3 Product hose kinked 4 Check valve not seating 5 Adjustment screw in too far 1 Load new BIB 2 Clean product hose or replace 3 Check...

Page 7: ...n For Postmix Beverage Dispenser With Low Pressure Faucet Remove Top Cover Remove Product And Hang Over Sides Of Dispenser Loosen Screw Slide Access Panel Toward Front And Remove After Access Panel Is...

Page 8: ...l Counter Clockwise For Stronger Mixture Or Clockwise For Leaner Mixture Make small adjustments approximately 1 points or 1 8 turn at a time After Adjustments Are Made Replace Access Panel Tighten Scr...

Page 9: ...Part No 803171 Issued 3 28 13 Rev 011515 9...

Page 10: ...Part No 803171 Issued 3 28 13 Rev 011515 10...

Page 11: ...Part No 803171 Issued 3 28 13 Rev 011515 11 Additional Parts 14410 Black Plastic Cover Small 803197 Drip Tray S S Grid...

Page 12: ...dial plate after the dial knob is removed This area is now open for cleaning and troubleshooting When reassembling dial knob to shaft be sure that the white indicator is in the same position as befor...

Reviews: