Part No. 803171 Issued 3-28-13 Rev 011515
5
1.
Follow steps 1-3 of cleaning instructions on page #3
2.
Shut off water supply valve on the back of the dispenser.
3.
Open and close faucet handle to relieve system of water.
4.
Unscrew the faucet handle/cap assembly from faucet.
5.
Wash the faucet/cap/seat cup assembly in a mild dishwashing soap and warm water.
6.
Reinstall assembly to faucet body taking care not to cross thread when installing. Finger
tight is adequate.
7.
Turn water supply on.
8.
Prepare one gallon of food grade sanitizing solution *(200 ppm available chlorine) in a
suitable container per the sanitizer manufacturers instructions. Use 100
F water.
9.
Place BIB connector into the sanitizing solution. Ensure connector is submerged to
bottom.
10.
Place a large vessel under the faucet. Lock or hold faucet open until container of
sanitizing solution is empty. DO NOT FLUSH UNTIL THE FOLLOWING MORNING
11.
Flush by reloading the dispenser with concentrate. Lock or hold faucet handle down
until the tea is dispensed from the faucet. Dispense three 8 oz. servings and discard.
* Sanitizing solution with 200 ppm available chlorine can be made by adding ½ oz.
(1 tablespoon) of regular household bleach(6% sodium hypochlorite solution) per gallon
of water.
Do’s and Don’ts
OPERATION
1. Do fully activate faucet handle when dis-
pensing drinks.
2. Do clean & sanitize dispensing assembly
weekly.
3. Do keep dispenser primed with concentrate
at all times.
4. Do reload immediately when out of con-
centrate.
5. Do flush and clean lines regularly.
6. Don’t forget to clean & sanitize faucet seat
cup
7. Do follow all cleaning and sanitizing pro-
cedures, remove and store concentrate if
urn will not be used for an extended period
of time; ie: more than two days.
INSTALLATION
1.
Do
connect dispenser to a filtered waterline.
2. Do flush filters before connecting to dispenser.
3. Do sample finished drink before making adjust-
ments.
4. Do make very slight drink adjustments then sam-
ple.
5. Don’t forget to flush filters before installation.
6. Don’t make any pressure regulator adjustments
on urn. (Do NOT attempt to adjust the urn regu-
lator. If a regulator adjustment is required call
the factory at 1-800-556-3926. The adjustment
should be made by a qualified service techni-
cian.)
7. Don’t forget to get sample approval from cus-
tomer.
WEEKLY SANITIZING
The following procedure Applies To Each Dispenser Head
Bag in Box