Summary of Contents for Duraline series

Page 1: ......

Page 2: ...Description of Parts and Application 2 6 Installation Instructions 7 Installation Diagram 8 Part Numbers and Descriptions 9 10 Iron Removal Complete System 11 Contact Information 12 ...

Page 3: ...The In Out Air Release Fitting R00019 comes pre assembled into the In Out Head R0005 Attach the Air Release System R00018 to the hose barb Refer to Installation Instructions 2 page 7 Refer to Figure 2 ...

Page 4: ... pre assembled and fixed to the Connection Manifold R0001 to create the Electronic Manifold Assembly R00020 The Spool Adapter with Check Valve R0006 is installed on the inlet side of the Connection Manifold R0001 with the Monitor Meter R0002 attached ...

Page 5: ... Elbow with Check Valve R0008 10 are included in the kit and will need to be taped and attached to the connection manifold R0001 See Figure 2C If you are not using the sample taps be sure to tape and attach the enclosed plugs instead ...

Page 6: ...ater The Air Pump R00010 connects with tubing that uses a quick release fitting on the pump and is routed to the Elbow with Check Valve R0008 10 Refer to page 4 Figure 2c The Air Pump Bracket R0009 is a stainless steel bracket that provides convenient means to permanently install the pump ...

Page 7: ...be used with quick release fittings and our standard bypass valve 1606P This allows for minimal water usage during the installation of the Iron Kit John Guest fittings are optional Standard Bypass Manifold Assembly with optional John Guest fittings Optional Stainless Steel Bypass Assembly ...

Page 8: ...on with the inlet to the in out head first and secure with provided clips Attach connection manifold assembly to the filter valve using provided clips 9 Tape and attach the air inlet elbow with check valve R0008 10 and both sample taps onto the bottom of the connection manifold If sample taps are not desired please install enclosed plugs 10 Attach plastic bypass to meter assembly connection manifo...

Page 9: ......

Page 10: ...PART DESCRIPTION QTY BYPASS MANIFOLD 1 R0007 SPOOL ADAPTER 2 116018HB 3 4 PLASTIC YOKE 1 R00018 AIR RELEASE SYSTEM PART DESCRIPTION QTY R0008 1 CONNECTOR 1 R0008 8 REDUCER 1 R0008 9 1 4 TUBING 8 INCHES R00011 CHECK VALVE CART 1 R00019 IN OUT AIR RELEASE FITTING PART DESCRIPTION QTY R0008 6 HOSE BARB 1 R0008 7 ELBOW 1 R00020 ELECTRONIC MANIFOLD ASSEMBLY PART DESCRITION QTY R0001 CONNECTION MANIFOLD...

Page 11: ...006 SPOOL CHECK VALVE ASSEMBLY 1 R0008 2 TAP 2 R0008 10 ELBOW with CHECK VALVE 1 R0009 AIR PUMP BRACKET 1 R00010 AIR PUMP 1 R00018 AIR RELEASE SYSTEM 1 R00019 IN OUT AIR RELEASE FITTING 1 R00020 ELECTRONIC MANIFOLD ASSEMBLY 1 SUB ASSEMBLY COMPONENT OPTIONAL COMPONENTS PART DESCRIPTION R0008 4 JOHN GUEST FITTING 1606KB METAL BYPASS 1606K 1 METAL BYPASS ...

Page 12: ...of manganese The air injection process requires careful control of the flow If water usage becomes to great not enough air is applied to oxidize the iron and manganese The advantage of the Hankscraft Iron Removal System is that the aeration is adjustable from immediate on demand to delayed aeration based on real time water usage and the oxidation process can be optimized R00030 IRON REMOVAL SYSTEM...

Page 13: ...Thank you for choosing this Iron Removal system for your water treatment Please contact your service professional with questions Place contact information here ...