background image

  

                     CONTENTS                                                                                          PAGE NUMBER

 

 

 

Installation

.......................................................................................... 

 

Brixing—Standard Manifold

.............................................................. 

 

Flow Regulator Manifold

.................................................................... 

 

Configuration and Maintenance

........................................................ 

 

Repair

…............................................................................................... 

6-8 

 

Model Numbers, Buttons, and Butterfly Plates

…........................... 

 

Butterfly Maps

.................................................................................... 

10-11 

 

Sanitizing and Cleaning

…………………………………………………. 

12-13 

 

Troubleshooting

………………………………………………………….. 

14 

 

Exploded Parts Drawings

………………………………………………. 

15-26 

 

 

 

SERVICE AND FACTORY ASSISTANCE: 

                                        

Please record your Installer/Service Agent's name and phone number here for future reference:

 

 

SERVICE AGENT NAME:    ___________________ 

DATE OF INSTALLATION: _______________

 

 

SERVICE AGENT PHONE:  ___________________  

  

  SERIAL NUMBER: ______________________

  

 

Or, call the Wunder-Bar Service Hotline 1-866-WUNDERBAR (1-866-986-3372) anytime or  

(707) 448-5151 Monday through Friday, 7:00 AM to 5:00 PM Pacific Time. 

MARK 4 MANUAL 

REV041410 

 

Mark 4 

POST-MIX  

BEVERAGE  

DISPENSER    

For 1 to 14 Button  

Post-Mix  

and  

Juice Dispensers 

Standard and Flow Regulator Manifold  

Copyright 1988, 2010 by Automatic Bar Controls, Inc. 

www.wunderbar.com 

Summary of Contents for Mark 4

Page 1: ...e and phone number here for future reference SERVICE AGENT NAME ___________________ DATE OF INSTALLATION _______________ SERVICE AGENT PHONE ___________________ SERIAL NUMBER ______________________ Or call the Wunder Bar Service Hotline 1 866 WUNDERBAR 1 866 986 3372 anytime or 707 448 5151 Monday through Friday 7 00 AM to 5 00 PM Pacific Time MARK 4 MANUAL REV041410 Mark 4 POST MIX BEVERAGE DISPE...

Page 2: ...f the mount ing hardware package to secure the tube collector manifold assembly to the underside of the bar A Kwik Mount kit is also available as an optional item It is recommended that a screw be placed in both the tube collector and the brix manifold to prevent unwanted flexing SANITARY DRIP CUP Fig 4 INSTALLATION INSTRUCTIONS 1 Position the PH10 121 Drip Cup Holder into the recess located under...

Page 3: ...ates and clockwise or in to decrease flow rates Fig 6 The brix screws are the exposed screws on the product manifold Do not turn the Shut Offs to adjust the brix ratio The shut offs are closest to the input fitting side of the manifold and are open when the Shut Off tabs or screw slots are in line with the flow of product through the manifold see Fig 7 Repeat the adjustment process to set the wate...

Page 4: ...ll air has been removed from the soda water and syrup lines Air will cause varying flow Also be sure to chill all liquid to its normal operating temperature to assure proper settings GENERAL OPERATING INSTRUCTIONS FOR FLOW REGULATORS Your Flow Regulator Manifold was factory pre set and tested to the following pressures and flow rates Achieving Finished Product Flow Rate of 1 5 Ounces Per Second 1 ...

Page 5: ... dis penser you must turn off all syrups water and carbonated water The manifold is equipped with shut offs or shut off screws for each of the syr ups the soda and the water Fig 12 The shut offs work like a gate valve There is a hole through the shut off that is aligned in the same direction as the shut off s tab handle This allows each beverage dis penser on the system to be shut off indi viduall...

Page 6: ... Remove the button plate Remove only the butterfly plates located directly above the stem O ring to be replaced Fig 17 Lift up and remove the O ring retainer plate from above the stem O ring that is to be replaced Fig 18 Use the spring end of the Stem O ring Removal Tool p n PH10 112 to stab and then remove the defective Stem O ring from the O ring cav ity Fig 19 Turn the spring end counterclockwi...

Page 7: ...f your hand using the tip of the metal stem on a spare valve plunger stem Figs 25 26 Install a replacement cream colored Santoprene rubber valve plunger stem back into the valve cavity all the way up through the stem O ring Position the locking hat plug with spring and O ring onto the slotted end of the locking hat plug tool Fig 24 Position the hat plug with spring and O ring into the valve cavity...

Page 8: ...isconnect the handle and sheathing assembly from the manifold Remove the Tube Collector Cover screws to gain access to the tube ends and inter connect fittings Lift up on the desired tube s interconnect fitting and unsnap it to separate it from the tube collector The Individual tube can now be re placed in the field Remove the four screws from the handle heel and slide the heel and sheathing away ...

Page 9: ...The half moon cut out area of the butterfly plates are where the retainer and retainer screws are located when attaching the plates to the handle When replacing butterfly plates be careful not to over tighten the retainer screws Over tightening the retainer screws can cause the butterfly plates to bind See the Butterfly Plate Maps on pages 10 and 11 of this manual EXPLANATION OF MODEL NUMBERS _ _ ...

Page 10: ...10 B U T T E R F L Y M A P MARK 4 MANUAL M4 10800 M4 10700 M4 10620 M4 8600 M4 10530 M4 8510 M4 10440 M4 10350 M4 10260 M4 10170 M4 10080 M4 12640 M4 12550 M4 12460 www wunderbar com ...

Page 11: ...11 B U T T E R F L Y M A P MARK 4 MANUAL M4 12820 M4 12730 M4 12640 M4 12550 M4 12460 M4 12370 M4 12280 M4 14840 M4 14750 M4 14660 M4 14570 M4 14480 www wunderbar com ...

Page 12: ...e Brush in Cleaning Solution as shown in Fig 1 2 Wrap the brush around the sheathing at the Heel end Fig 2 Move the brush up and down the entire length of the Sheathing from Heel to Manifold Fig 3 a minimum of 6 times 3 Immerse the Brush in the Cleaning Solution Rotate the Sheathing Brush 1 2 turn Move the Brush up and down the entire length of the Sheathing 6 more times 4 Immerse the Sheathing Br...

Page 13: ...uttons 4 Allow the cleaning solution to remain in the system for a minimum of two minutes Then proceed to step 5 RINSE INSTRUCTIONS RINSE INSTRUCTIONS 5 Rinse and fill the Sanitizing Tank or Bucket with clean warm water 100 F 38 C 6a SANITIZING TANK Attach the BIB connector to the Sanitizing Tank outlet s Fig 2 to RINSE one syrup circuit at a time or to a tank manifold if so equipped to RINSE mult...

Page 14: ...perly Check CO2 supply and regulators adjust to correct settings Check CO2 supply to carbonator set high pressure regulator between 95 105 PSI Check brix screw on soda and or water positions Check brix screws on product Check to be certain shut off screw slots are in proper position Flow runs in same direction as slot Rebrix the dispenser PROBLEM Product s taste strong or syrupy POSSIBLE SOLUTION ...

Page 15: ...15 15 www wunderbar com ...

Page 16: ...16 16 www wunderbar com ...

Page 17: ...17 17 www wunderbar com FR 73 ...

Page 18: ...18 18 www wunderbar com ...

Page 19: ...19 20 www wunderbar com ...

Page 20: ...20 19 www wunderbar com ...

Page 21: ...21 21 www wunderbar com ...

Page 22: ...22 www wunderbar com 22 FR 73 ...

Page 23: ...23 23 www wunderbar com ...

Page 24: ...24 24 www wunderbar com ...

Page 25: ...25 25 www wunderbar com ...

Page 26: ...26 26 www wunderbar com ...

Reviews: