Page 147/ 191
22.5.3 BAM Settings
The VDR can be connected to a Bridge Alert Management (BAM) system if available. When
enabled VDR alert messages will be transmitted to the BAM system. Full details of alert identifiers
are available in the
Figure 22.5.3.1
– Configurator page, BAM settings
BAM Enabled Slider
Used to enable (as shown) or disable BAM.
BAM Interface
Used to enable the ports used for BAM transmission.
Se
lect “
default
” to transmit BAM messages via the ethernet network using LWE.
Select “
Serial
” to transmit alert messages by using an output port on the BCU or Bus
Coupler.
Summary of Contents for NW6000
Page 1: ......
Page 91: ...Page 91 191...
Page 92: ...Page 92 191...
Page 120: ...Page 120 191 Figure 17 4 2 Connection figure Digital Module 16 channels...
Page 121: ...Page 121 191 Figure 17 4 3 Connection figure Digital Module 24 channels...
Page 125: ...Page 125 191 Figure 18 4 2 Connection figure Analogue Module 8 channels...
Page 126: ...Page 126 191 Figure 18 4 3 Connection figure Analogue Module 12 channels...
Page 184: ...Page 184 191 Figure 5 8 1 Sample dataset playback...