Restore to factory setting
Z311C is capable of data storage on power failure. If Z311C is unable to communicate
with its registered CIE device or if you wish to join it to a new network, a restore to factory
default is required
Operation:
Hold press auxiliary key and binding key
together you should see
2 red flashes
on the
indicator but do not release the keys yet at this time until you see another quick flashes
followed then release the keys. The device should restore to the factory setting and soon
enters
power off mode
automatically to save power.
Battery level reporting
Low power reporting
The working voltage for Z311C is between 2.1~3.6V DC. It performs the first battery level
check when the battery is loaded. The device performs battery level check in a period of
time. Anything bellow 2.1V, a battery-low report is sent to the network and its enrolled CIE.
Battery Level Notification
Z311C not only reports low power notification to notify the user but also sends battery
level in percentage value. This information is placed in Zone Status Change Notification
and is sent when the statues of Z311C changes.
Battery disposal
This device uses 2 CR2450 3volt button batteries. When the battery is bellow 2.1V DC,
the device will not work and the status indicator will steadily flashing to notify the user to
replace it.
Warning: Do not cast battery into the fire. The battery may be explosive and may cause
injuries.