When the battery is loaded, Z311C enters power off mode. This ensures minimum power
losses. Any other button press or contacts will not activate power except binding key.
Turn it on
Please go to Step 2 now before you turn it ON.
To turn it on,
short press binding key once
and you will see the red indicator flashes
once. Now the power is on and the device is ready to search for any available network on
the air.
Turn it off
At any time when you want it to be off when it will not be used, you can simply short press
the binding key once the red indicator will
flashes 10
times for 5 seconds.
Before
5
seconds
expires press the binding key again to turn it off. You will see the red light goes
off. If 5 seconds has expired and the key press is not applied within the period, Z311C will
return to power on condition.
* It is recommended to power off Z311C when not in use.
Z311C is a zone device in the security system. Soon after the network join, the next step is
to enroll itself into a CIE (Control and Indicating Equipment) security system device to
validate zone alarm feature. The registration will take place automatically soon after the
device joined to the network.
*notes: a CIE security system will normally embedded within a device (i.e. a Netvox
Z201B) or it could be a stand-alone CIE device.
Observing CIE registration:
To ensure enrollment is successful or not simply read the indicator light flashes:
(1) Right after the network join, see if red indicator light flashes
twice
indicating that there
is no CIE existed or no compatible CIE is on the network.
(2) If there is CIE and it has enrolled, Z311C will send an enrollment request to it.
If
enrollment failed the red indicator flashes 4 times. Flash 6 times if successful.
(3) For any reason that Z311C has failed being registered,
press the Auxiliary key
at
anytime should initiates the registration process. The LED indicator will flash the same
as that described in (2).
S
tep 2.
Automatic Zone Registration (enrollment)