Enter your desirable Heartbeat period in Hour, in Minute and in Second. Set anything
between 30 seconds to 168 hours
Then Click
Set Heatbeat
when done to sent this configuration to the remote Z311C.
Assigning Z311C to a preferred CIE system
Assigning the preferred CIE settings please follow the
Configuring Heartbeat of Z311C
in
the previous
section. In Figure 4 if Z311C has registered in a CIE system, the CIE system
device IEEE address will be displayed otherwise it will be blank.
Click on the dropdown arrow next to the IAS CIE ADDRESS and select a preferred CIE
system device.
*Now make sure you have wake up Z311C device which normally go to sleep when idle.
On how to wake up Z311C please go to
Overcoming a sleeping device
section.
-Now click on the
Set IAS_CIE_ADDRESS
to send the setting to Z311C device.
*Notice: Z311C is an end device which runs on battery power. It is normally at sleep
mode when idle except at each heartbeat cycle. So before you click
Set Heatbeat
,
make sure you wake up the sleeping device so that it will be up and listening. On how
to wake up Z311C please go to
Overcoming a sleeping device
section.