How to use
After Z311C has registered to the security system it is on duty for intrusion monitoring. Any
changes in device status will be reported to the CIE security system. For installation
please read
the Installation section
.
Door/window application
When the internal magnetic contact piece is near or attached on the Z311C, the status is
normal (Figure A) and is reported to the CIE security system.
When the magnetic contact piece moved away from Z311C, the device changes its status
to alarm mode and a zone status change is reported to CIE system. Normally the siren or
a silent alarm device in the network will be triggered. In case that the device is not
registered to a CIE system, it will try to register first then sent out an alarm notification at
once.
Note:
1. CIE device must be always existed elsewhere in the network.
2. It is commended that only one status change within 2 seconds to avoid potential traffic
jam of communication.
Glass break detection application
The glass breaking vibration wave would cause the sensor attached on the glass to
vibrate which trigger the alarm status of Z311C; following this Z311C would read other two
door magnetic contacts conditions. If the door contacts are closed, the normal status is
restored and normal status is then reported. If the door contacts are open the alarm status
stays –alarm status and no status message is reported. In this case the alarm status is
uninterrupted which continues signaling to either siren devices or strobe lighting devices.
In case that somehow Z311C was not registered to the CIE security system, a door close
or open; or glass break detection would wakes up the device to initiate registration
process and sent status report to CIE device at once. This ensures the up time of the
monitoring device. Unregistered situation can be the absence of the CIE device in the
network either due to CIE device maintenance reason or a new CIE device introduced.