MultiPro 2000 User Manual 

 

 

 

 

Copyright 

 

Copyright  ©  2015  by  Netech  Corporation.  All  rights 

reserved.  No  part  of  this  publication  may  be 

reproduced or transmitted in any form other than for 

the  purchaser’s personal  use  without  written 

permission from Netech Corporation. 

 

Quality Assurance

 

 

Netech  Corporation  is  ISO  9001-2008  Certified.  This 

instrument  was  thoroughly  tested  and  inspected 

according  to  Netech’s  ISO  QS  standards  and  test 

procedures,  and  was  found  to meet  those 

specifications when  it  was  shipped  from  the factory. 

Calibration measurements are traceable to National 

Institute of Standards and Technology. A calibration 

certificate is included with the unit.   

 

Technical Support

 

 

For technical support questions either email 

for fast response.   

 

Trade Marks 

 

 

Netech and MultiPro 2000 are the trade mark  of 

Netech Corporation. Any trade mark reference used in 

the manual are only for editorial purpose and the 

benefit of the respective trademark owner, with no 

intention of improperly using that trade mark.  

 

Manufacturing Location 

 

Netech Corporation, Farmingdale, NY 11735

Summary of Contents for 560-110

Page 1: ...USER MANUAL MultiPro 2000 PN 560 110 110 VAC PN 560 220 220 VAC Advanced Electrical Safety Analyzer Multi Parameter Simulator 110 Toledo Street Farmingdale NY 11735 www NetechCorp us...

Page 2: ...anual so that you will be able to properly use and maintain this product We welcome any comments you may have that could help us improve the MultiPro 2000 and this manual Netech is recognized as an in...

Page 3: ...et those specifications when it was shipped from the factory Calibration measurements are traceable to National Institute of Standards and Technology A calibration certificate is included with the uni...

Page 4: ...improper use Safety Considerations Read all safety information prior to use Do not apply more than the rated input voltage Do not connect a device that exceeds the rated current Do not use the unit a...

Page 5: ...se Leakage Using External Leads 19 External Leakage Point to Point Measurement 20 Leads Leakage 21 Power Cord Ground Resistance 24 Simulator Function 25 Save and Print Test Results 27 Saving test resu...

Page 6: ...Analyzer is a measurement device as well as a waveform simulator The Analyzer is capable of saving over 5000 test records and can be uploaded to a PC for printing and record keeping using the softwar...

Page 7: ...unctions are available ECG Normal Sinus Rhythm NSR Performance SIN SQUARE TRIANGLE PULSE User selectable Amplitude and rate The waveform output is through the 10 color coded ECG snap posts marked RL L...

Page 8: ...and the operation of the unit Instrument Familiarization Display The Multi Pro 2000 incorporates a vacuum fluorescent display The display ensures high readability even under the lowest ambient light...

Page 9: ...eads Leakage Function Key Pressing the key enables the LEADS LEAKAGE Menu selections RESISTANCE MEASUREMENT Resistance Measurement key enables the power cord ground wire resistance measurement menu wi...

Page 10: ...cted using the keypad to energize the test receptacle during leakage measurement functions Menu Functions and Operation The operation of the MultiPro 2000 is Menu driven It is simple and easy to use f...

Page 11: ...oftware upgrade and other factory settings In addition to the MAIN MENU function dedicated keys are provided for each of the main functions They are described as follows CASE Leakage Case Leakage curr...

Page 12: ...MultiPro 2000 User Manual 12 OFF Enables the Power the outlet to turn off REVERSE POLARITY Set the outlet to reverse...

Page 13: ...will perform a series of self tests and momentarily display the model name and the software version followed by the MAIN MENU as shown below Menu Descriptions Before connecting the DUT Device Under Te...

Page 14: ...f normal polarity will be activated and the unit DUT will turn on Press ESC to go back to the previous Menu INTERNAL MEASUREMENT Menu POL Polarity Check of the Inlet Power From the INTERNAL MEASUREMEN...

Page 15: ...2000 is capable of storing over 5000 test results in the Non volatile memory and can be uploaded to a PC to save or print the records The Save option is available in all the measurement Menu refer to...

Page 16: ...ready entered for the unit under test press F4 N0 Note When testing multiple units it is important to change the ID as the test records are saved under this ID number TIME Time re setting Function Pre...

Page 17: ...Normal Polarity Reverse Polarity Open Neutral OFF Select the desired polarity The Earth leakage measurement is through the internal ground conductor and the external test lead is not required To meas...

Page 18: ...eature of the MultiPro will select the appropriate range automatically For reading in excess of 100 micro amps the decimal point will not be displayed The user can switch between Reverse and normal Po...

Page 19: ...e case leakage Enclosure leakage attach the external Kelvin cable to the case conductive surface of the DUT device under test Select the desired polarity and press READ The display will indicate the l...

Page 20: ...used to measure Leakage current flowing from any conductive surface of the DUT and Earth ground From the MAIN MENU select XTR F3 Key EXTERNAL LEKAGE Menu will be displayed with the prompt to connect t...

Page 21: ...t patient connections The following two modes of measurement function available as shown in Screen Shot 5 GND Measures current flowing through the leads to ground In this option leakages of individual...

Page 22: ...an isolated AC voltage equal to or 10 higher is applied to the leads and earth ground The voltage is current limited but it is lethal DO not touch the exposed metal parts of the ECG post or the analyz...

Page 23: ...WHILE THE PATIENT IS CONNECTED TO A RELATED POWER SYSTEM BRANCH CIRCUIT This test verifies that the isolation system on the device under test is operating properly The following block diagram shows th...

Page 24: ...e Once Kelvin cable is attached to a suitable ground on the device under test press the READ switch on the front panel the unit will determine the resistance in 3 seconds Ground resistance will be dis...

Page 25: ...to 4 5 mV Performance Waveform o SINE TRIANGLE SQUARE PULSE o Rates 0 1 to 60 Hz o Amplitudes 0 1 to 4 5 mV Connect the ECG leads to the respective ECG Snap posts If the DUT is off press the Normal Po...

Page 26: ...the waveform is displayed as shown in Screen Shot 7 The amplitude and rate selection can be done from this Menu Amplitude selection can be achieved by using F1 to F6 keys indicates the additional sele...

Page 27: ...g F1 Saving test results in the internal memory To save the test result Press F1 from the measurement menu as shown Screen Shot 8 After saving the test results of the DUT s under test it can be upload...

Page 28: ...The software is compatible with Windows XP and Windows 7 Run the ProComPrintSetup from the CD by double clicking on the ProComPrintSetup exe Follow the on screen instructions When the installation is...

Page 29: ...ProComPrint Version 1 0 Features The ProComPrint Ver 1 0 included with the unit is a basic version of the optional customizable database version This will earnable the user to quickly connect the Mult...

Page 30: ...een Select Equipment ID If multiple units are being tested the results of the individual units can be down loaded by selecting the Equipment ID using the v arrow CLR MEMORY This will clear all the sav...

Page 31: ...as shown below is included in the ProComPrint Ver 1 0 Note Sample Data Sheet can be opened and printed only if a licensed copy of the word is installed in the PC The test results that are saved will b...

Page 32: ...the Print menu options HEAD Select F1 for uploading a blank header with user editable fields RESULT Select F3 for uploading all saved test results CLR Select F6 for clearing all the records saved in t...

Page 33: ...Range Auto range 0 to 99 9 100 to 2000 uA Accuracy DC to 100 Hz 1 of the reading 2 uA 100 Hz to 1 kHz 2 of the reading 3 uA 1 kHz to 1 MHz 10 of the reading 10uA Current Range 0 99 9 100 2000 Micro A...

Page 34: ...um 220 Volt Units PN 560 220 180 VAC to 260 V AC to 130 V 50 Hz to 60 Hz 16 A Maximum Simulator NSR Normal Sinus Rate 30 60 70 80 90 100 120 150 180 210 240 270 and 300 BPM Accuracy 1 1 BPM Amplitude...

Page 35: ...nnual recalibration Netech recalibration charges are very low compared to the industry standard Any firmware or software update will be done during annual recalibration at no additional cost Field cal...

Page 36: ...damage instruments Malfunction Please follow these steps for repair or re calibration of your NETECH instrument 1 Obtain an RMA Return Merchandise Authorization by calling Netech Customer Service 1 6...

Page 37: ...at its factory in Farmingdale New York USA Netech support its products longer than any other manufacturer in this field All Netech Products are manufactured in the USA We are proud to serve the globa...

Page 38: ...arts and Accessories Part Number Description 560 110 MultiPro 2000 Safety Analyzer 110 V 560 220 MultiPro 2000 Safety Analyzer 220 V 560 503 Test Lead set of two 560 HRD CASE Hard Carrying case 560 55...