Terminating CIFS can cause loss of data.
◦
If the command fails because the partner "not ready", wait 5 minutes for the NVMEMs to synchronize.
◦
If the command fails because of an NDMP, SnapMirror, or SnapVault process, disable the process. See
the appropriate Documentation Center for more information.
5. Wait 3 minutes and check the failover status with the
storage failover show
command.
6. At the clustershell prompt, enter the
net int show -is-home false
command to list the logical
interfaces that are not on their home node and port.
If any interfaces are listed as
false
, revert those interfaces back to their home port using the
net int
revert
command.
7. Move the console cable to the target node and run the
version -v
command to check the ONTAP
versions.
8. Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
9. Use the
storage encryption disk show
at the clustershell prompt, to review the output.
10. Use the
security key-manager key query
command to display the key IDs of the authentication
keys that are stored on the key management servers.
◦
If the
Restored
column =
yes/true
, you are done and can proceed to complete the replacement
process.
◦
If the
Key Manager type
=
external
and the
Restored
column = anything other than
yes/true
,
use the
security key-manager external restore
command to restore the key IDs of the
authentication keys.
If the command fails, contact Customer Support.
◦
If the
Key Manager type
=
onboard
and the
Restored
column = anything other than
yes/true
,
use the
security key-manager onboard sync
command to re-sync the Key Manager type.
Use the
security key-manager key query
command to verify that the
Restored
column =
yes/true
for all authentication keys.
11. Connect the console cable to the partner node.
12. Give back the node using the
storage failover giveback -fromnode local
command.
13. Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
Return the failed part to NetApp - AFF A320
After you replace the part, you can return the failed part to NetApp, as described in the
RMA instructions shipped with the kit. Contact technical support at
, 888-
463-8277 (North America), 00-800-44-638277 (Europe), or +800-800-80-800
(Asia/Pacific) if you need the RMA number or additional help with the replacement
procedure.
29