AlphaDisc CLD user guide V2.0
56
4.5.1.3 Site Tabs
Once selecting the Site to interface the filter, the application has 5 tabs.
Scroll through these tabs by swiping to the right or to the left. You may also reach the desired tab by clicking on the
designated icons that appear at the bottom of the screen.
4.5.1.3.1 The Online Status Tab
4.5.1.3.2 The Counters Tab
ELEMENT
DESCRIPTION
THE UPPER RED / GREY LINE
DISPLAYS THE NAME OF THE CURRENTLY CONNECTED CONTROLLER AND THE
COMMUNICATION STATUS (CONNECTED / DISCONNECTED).
TIME FROM LAST FLUSH
THE TIME SINCE THE END OF THE LAST FLUSH CYCLE.
LAST FLUSH CAUSE
THE TRIGGER THAT INITIATED THE LAST FLUSH.
PRESSURES - INLET
THE CURRENT READING OF THE FILTER'S INLET PRESSURE.
PRESSURE - OUTLET
THE CURRENT READING OF THE FILTER'S OUTLET PRESSURE.
PRESSURE - DP
THE PRESSURE DIFFERENTIAL ACROSS THE FILTER; CALCULATED BY SUBTRACTING THE
OUTLET PRESSURE FROM THE INLET PRESSURE.
MANUAL FLUSHING
CLICK THIS ICON TO START A MANUAL FLUSH CYCLE.
ELEMENT
DESCRIPTION
THE UPPER RED / GREY LINE
DISPLAYS THE NAME OF THE CURRENTLY CONNECTED CONTROLLER AND THE
COMMUNICATION STATUS (CONNECTED / DISCONNECTED).
LAST RESET AT:
THE DATE OF THE LAST RESETTING OF THE COUNTERS.
DP CYCLES
THE NUMBER OF FLUSH CYCLES STARTED DUE TO A DP SIGNAL.
FLUSHING INTERVAL CYCLES
THE NUMBER OF FLUSH CYCLES STARTED DUE TO THE TIME INTERVALS PROGRAM. ALSO
COUNT THE ANTIFREEZE PROTECTION INTERVALS FLUSHES
PRESET
THE NUMBER OF FLUSH CYCLES STARTED DUE TO THE PRESET DAILY START TIME AND THE
CURRENT STATUS OF THIS PROGRAM.
MANUAL CYCLES
THE NUMBER OF FLUSH CYCLES STARTED DUE TO A MANUAL START COMMAND ISSUED BY
THE USER.
TOTAL FLUSHING CYCLES
THE TOTAL NUMBER OF FLUSH CYCLES STARTED FOR ANY REASON.
RESET BUTTON
CLICK THIS BUTTON TO RESET THE COUNTERS TO ZERO.