7
MERLIN STEALTH
Installer Options
GATE 2 DELAY TIME
The time delay for the gate to stay open before the alarm is activated, can be changed by
pressing the
1
key, followed by the
2
key. Select the desired time delay from the table and
press the corresponding number from
0 to 9
followed by the
#
key. The keypad will beep twice
to indicate that the new setting was accepted.
Example: To change the Gate Delay Time to 4 minutes,
enter 1 2 8 #
HIGH POWER FENCE VOLTAGE
The open circuit fence voltage can be changed by pressing the
0
key, followed by the
5
key.
Select the desired voltage from the table and press the corresponding number from
0
to
9
followed by the
#
key. The keypad will beep once to indicate that the setting was accepted.
Example: To change open circuit Fence Voltage to 6kV6 on a M15, enter
0 5 2 #
M15 & M25 M18 & M28
Typical readings Typical readings
0
2 Sec
1
5 Sec
2
10 Sec
3
30 Sec
4
45 Sec
5
1 Min
6
2 Min
7
3 Min
8
4 Min
9
4 Min 30 Sec
V peak
open
circuit.
Volts
V peak
500 ohm
load
Energy
(500 ohm
load) J
0
6000
3900
2.50
1
6300
4150
2.80
2
6600
4300
3.00
3
7100
4500
3.20
4
7500
4850
3.70
5
7750
5050
4.00
6
7900
5200
4.20
7
8100
5300
4.40
8
8300
5450
4.60
9
8500
5600
4.80
V peak
open
circuit.
Volts
V peak
500 ohm
load
Energy
(500 ohm
load) J
0 8000 auto
7100
6.8
1
7000
4500
3.20
2
7700
4950
3.70
3
8200
5300
4.20
4
8500
5650
4.80
5
8900
5950
5.20
6
9200
6850
6.40
7
9300
7100
6.80
8
9300
7350
7.30
9
9300
7600
7.60