9
MERLIN STEALTH
Installer Options
STROBE LIGHT FUNCTION
The strobe light outputs can be used for alarm indication or fence On/Off ( Zone 1) and high/low
voltage (Zone 2) indication. This can be changed by pressing the
1
key followed by the
0
key.
Select the desired function from the table and press the corresponding number from
0
or
1
followed by the
#
key. The keypad will beep three times to indicate that the new setting was
accepted.
Example: To change the Strobe Light Function so that the strobe
light switches on whenever the fence is on, enter 1 0 1 #
The default Strobe Light Function is option 0, the strobe light output indicating an alarm
condition.
MAGNETIC SWITCH FUNCTION
The magnetic switch may be disabled if a keypad or remote On/Off switch is used. This can be
changed by pressing the
1
key followed by the
0
key followed by the desired 2 or 3.
Example: To disable the magnetic switch enter 1 0 2 #
By default the magnetic switch is functional.
KEYPAD DETECT FUNCTION (NOT AVAILABLE)
The energizer can be configured to detect if one or more keypads is present. The keypad detect
function can be altered by pressing the 1 key, followed by the 0 key. Select the desired state
from the table and press the corresponding number from 6 to 7 followed by the # key. The
keypad will beep twice to indicate that the new setting was accepted.
Example: To enable the keypad detect function,
enter
1 0 6 #
(detection period is 15 seconds)
By default the Keypad detect is
off
.
0
Strobe light = Alarm
1
Strobe light = fence ON
2
Magnetic Switch disabled
3
Magnetic Switch enabled
6
Keypad detect on
7
Keypad detect off