6
MERLIN STEALTH
Installer Options
Example: To change the Number of Events allowed to
8, enter
0 3 7 #
ALARM RE-ARM TIME
The alarm annunciation process may be repeated after a re-arm period. The re-arm time for the
system can be changed by pressing the
2
key, followed by the
0
key. Select the desired re-arm
time from the table and press the corresponding number from
0
to
9
followed by the
#
key. The
keypad will beep three times to indicate that the new setting was accepted. Do not alter without
understanding the ramifications! On turning the system OFF and On again manually all alarm
timers and counters are reset. Please see attached
ALARM SETTING EXAMPLES.
Example: To change the re-arm time to 4 days, enter
2 0 6 #
GATE 1 DELAY TIME
The time delay for the gate to stay open before the alarm is activated, can be changed by
pressing the
0
key, followed by the
4
key. Select the desired time delay from the table and
press the corresponding number from
0 to 9
followed by the
#
key. The keypad will beep twice
to indicate that the new setting was accepted.
Example: To change the Gate Delay Time to 1 Minute,
enter 0 4 5 #
0
1 Event
1
2 Events
2
3 Events
3
4 Events
4
5 Events
5
6 Events
6
7 Events
7
8 Events
8
9 Events
9
16 Events
0
20 Sec
1
6 Hr
2
12 Hr
3
24 Hr
4
2 Days
5
3 Days
6
4 Days
7
5 Days
8
6 Days
9
7.7 Days
0
2 Sec
1
5 Sec
2
10 Sec
3
30 Sec
4
45 Sec
5
1 Min
6
2 Min
7
3 Min
8
4 Min
9
4 Min 30 Sec