XR-HK – HOOK PENDANT INSTALLATION
Refer to alternate instructions if using Pendant, Wall, Pole or Yoke Mount
Step 3
STEP 1.
Inspect shipping package and contents to ensure no damage has
occurred during shipping.
STEP 2.
It is recommended to install Secondary Safety Cable by looping
appropriate steel cable or chain through the outer band of the unit and
fastening a closed loop. Secondary safety hardware must be rated for a
minimum of 110lbs. Secondary safety cables made from stainless steel
aircraft cable are available upon request.
STEP 3.
Slide anti-rotation lock onto suspension hook assembly and install hook
assembly into ¾ NPT threaded entry. Tighten to hand tight plus 1 to 2
turns. Slide anti-rotation lock into place and tighten set screw to lock
unit in place.
NOTE:
To aid in assembly and provide protection against ingress, use of a petrolatum
or soap thickened mineral oil based thread lubricant/sealant is necessary.
Un-used conduit opening must be plugged to maintain the integrity of the
enclosure.
STEP 4.
Latch hook onto eye-bolt or other fixed mounting loop. Mounting point
must be rated for a minimum of 110lbs.
STEP 5.
Install remaining loop of secondary safety chain or steel cable to
suitable mounting location and fasten securely.
STEP 6.
Resume installation instructions provided with luminaire. (STEP 4 in XR
Installation Instructions from the Surface/Ceiling Mount installation
provided with Luminaire).
Step 2
This XR-HK kit is intended for use with UL Listed XR luminaire as
marked on the luminaire nameplate.
Accessory Package Contents
INSTALLATION STEPS
XR-HK
PART NAME
QTY
1
1
PENDANT HOOK ASSEMBLY
ANTI-ROTATION ASSEMBLY
TM
Nemalux
I N D U S T R I A L
XR-GEN
rev. A-13
9-14
www.nemalux.com | [email protected] | Tel 403•242•7475 | Fax 403•243•6190