XR-YM – YOKE MOUNT INSTALLATION

Refer to alternate instructions if using Conduit, Hook, Pole or Wall Mount

STEP 1.

Inspect shipping package and contents to ensure no damage has occurred 

during shipping.  

STEP 2.

Make wiring connections from branch circuit conductors to factory 

provided lead wires using one of the 3/4" NPT threaded entries. Follow 

wiring method requirements of the Canadian Electrical Code or National 

Electrical Code for the location of the installation. 

NOTE:

To aid in assembly and provide protection against ingress, use of a petrolatum or 

soap thickened mineral oil based thread lubricant/sealant is necessary.

Un-used conduit opening must be plugged to maintain the integrity of the 

enclosure.

STEP 3.

Loosely assemble Yoke mount with carriage bolts on inside and washers 

and nuts on the outside. 

NOTE: 

Depending on which mounting hole is used in the curved slot, the luminaire may 

be configured for an upward or downward adjustable swing. 

STEP 4.

Thread installed wiring through openings in yoke mount cheek plate and 

yoke mount bracket. Mount yoke assembly to luminaire using 4x M6 Socket 

Head Cap Screws and Washers (Provided). Torque fasteners to 5 Nm (45 

in-lbs).

STEP 5.

Mount luminaire assembly to desired location using 4x 1/4-20 OR M6 

Screws or Bolts (Not Provided).

STEP 6.

Adjust and aim luminaire to desired position. Torque hardware nuts to 9 

N-m (80 in-lbs).

STEP 7.

Resume installation instructions provided with luminaire. (STEP 4 in XR

Installation Instructions from the Surface/Ceiling Mount installation

provided with Luminaire).

Step 5

Step 3

This XR-YM kit is intended for use with UL Listed XR luminaire as 

marked on the luminaire nameplate.  

Accessory Package Contents

INSTALLATION STEPS

XR-YM

PART NAME

QTY

1

1

1

4

4

4

4

YOKE MOUNT A

YOKE MOUNT B

CHEEK PLATE

1/4-20 HEX NUT

1/4" FLAT WASHER

1/4-20 x 0.5in CARRIAGE BOLT

M6 x 25mm HEX HEAD CAP SCREW

TM

Nemalux

I N D U S T R I A L

XR-GEN

rrev. A-13

8-14

www.nemalux.com  |   [email protected]  |   Tel 403•242•7475  |   Fax 403•243•6190 

MADE IN CANADA

Summary of Contents for XR-GEN Series

Page 1: ...Class 1 Wiring only All supply field wiring must be rated 300V minimum for luminaires with suffix AC 600V minimum for luminaires with suffix HV Ambient Temperature Range XR8 50 C to 75 C XR10 50 C to...

Page 2: ...via retention strap Note Screws are captive fasteners and will remain attached to the cover for ease of reinstall and to prevent loss of fasteners 5 0in 126mm 5 2in 132mm 16 0in 405mm 17 3in 441mm 0...

Page 3: ...0 A for control needs 0 10V Controller must sink current from LED driver 0 10V control connections NOTE To aid in assembly and provide protection against ingress use of a petrolatum or soap thickened...

Page 4: ...REEN VIOLET GREY TM Nemalux I N D U S T R I A L XR GEN rev A 13 4 14 www nemalux com sales nemalux com Tel 403 242 7475 Fax 403 243 6190 MADE IN CANADA Any additional wiring not shown has been capped...

Page 5: ...ead lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of the enclosure STEP 5 Insert and tension M6 set screw to pole to lock rotation STEP 6 Resume inst...

Page 6: ...ly gasket to mount with adhesive backed side Torque to 5 Nm 45 in lbs STEP 5 Install Back Cover Plate with 4x M4 Flat head screws and adhesive backed gasket Apply gasket with adhesive side applied to...

Page 7: ...assembly Torque fasteners to 5 Nm 45 in lbs STEP 5 Thread installed wiring through opening in XR high vibration yoke mount and install XR luminaire into yoke The raised circular bosses on the XR cheek...

Page 8: ...curved slot the luminaire may be configured for an upward or downward adjustable swing STEP 4 Thread installed wiring through openings in yoke mount cheek plate and yoke mount bracket Mount yoke asse...

Page 9: ...ly and provide protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrit...

Page 10: ...n through the outer band of the unit and fastening a closed loop Secondary safety hardware must be rated for a minimum of 110lbs Install remaining loop of secondary safety chain or steel cable to suit...

Page 11: ...dy near AC input Secure the surge protector and driver lead wires together as close to the origin of the driver lead wires as possible using the provided zip tie STEP 4 Wire according to wiring instru...

Page 12: ...t conductor and White leads from LED Drivers 3 Connect Green wire from surge protector to splice or terminal connected to Grounding branch circuit conductor and green lead from luminaire case PS 1 GRO...

Page 13: ...provided zip tie STEP 4 Wire according to wiring instructions on Page 12 14 Refer to NEC CEC codes and follow all applicable local standards STEP 5 Close XR Wiring Cover Ensure the retention cable is...

Page 14: ...t conductor and White leads from LED Drivers 3 Connect Green wire from surge protector to splice or terminal connected to Grounding branch circuit conductor and green lead from luminaire case PS 1 GRO...

Reviews: