1. Disconnect Line Input branch circuit conductor from splice or terminal
connected to Black leads from LED Driver. Re-connect Line Input branch
circuit conductor to Black wire from surge protector.
2. Connect White lead from surge protector to splice or terminal
connected to Neutral Input branch circuit conductor and White leads
from LED Drivers.
3. Connect Green wire from surge protector to splice or terminal
connected to Grounding branch circuit conductor and green lead from
luminaire case.
PS 1
GROUND
(Factory)
BLACK
WHITE
WHITE
GREEN
BL
ACK
VIOLET
GREY
SURGE
SUPPRESSOR
WIRING DIAGRAM
(XR-SP-HV)
GREEN
WHITE
BLACK
-
LINE
WHITE
-
NEUTRAL
GREEN
-
GROUND
VIOLET
-
DIM
(+)
GREY
-
DIM
(-)
TM
Nemalux
I N D U S T R I A L
XR-GEN
rev. A-13
14-14
www.nemalux.com | [email protected] | Tel 403•242•7475 | Fax 403•243•6190
MADE IN CANADA