FlexPAK 800/1000 DX
27
EN
NOTE!
If a message is displayed that is not shown in this user manual, see the PLC Settings
Manual for more information.
NOTE!
If a warning or alarm is displayed that is not shown in this user manual, see the
PLC Settings Manual for more information and contact a Nederman authorized service
technician.
6.1
Status messages
The following status messages give information about what mode the unit is in or what
routine service is being performed.
6.1.1
Nederman FlexPAK Off (Off mode)
The unit is in Off mode, which is also the unit’s start menu. The unit can also go into Off
mode if something is wrong, such as if an alarm is activated. The pump motor is off, there is
no vacuum, the FCV is closed, and the unit cannot be activated by a pilot signal.
ESC
OK
FlexPak
Hi Vacuum Unit
OFF
Time To Service
2000 hours
TimeToService: The amount of time until next scheduled service. The
default setting is 2000 hours.
6.1.2
FlexPAK Standby (Standby mode)
The unit is in Standby mode. The pump motor is off, there is no vacuum, the FCV is closed,
and the unit is waiting for a pilot signal to go into Running mode.
ESC
OK
NEDERMAN
FLEXPAK
Standby
Wai
ti
ng For
Pilot Signal
Mo 15:33
6.1.3
Running (Running mode)
The unit in Running mode. The pump motor is on and the unit generates a vacuum. The
FCV is closed. The current vacuum of the unit is shown on the display, for example, -20 kPa.
ESC
OK
Running
kPA -20
DIRTm
00:00 s
OTTmr
00:00 h
Exhaust
Air Temp 60°C
DIRTm: The amount of time before the unit goes into Idling mode. The
default is 10 seconds.
OTTmr: If the Overtime timer has been activated, OTTmr shows the
elapsed time since the overtime timer started.
6.1.4
FlexPAK Idling (Idling mode)
The unit in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open.
The unit goes into Idling mode when there has been no pilot signal for the time set in DIR_
Time.
ESC
OK
FlexPak
Hi Vacuum Unit
IDLING
Time To StandBy
05:33m
TimeToStandby: The amount of time until the unit goes into Standby
mode. The default setting is 12 minutes.
Summary of Contents for FlexPAK 800 DX
Page 2: ...FlexPAK 800 1000 DX 2...
Page 9: ...FlexPAK 800 1000 DX 7 A B C 4A 3 13 12 10 9 7 8 2 1 3 4 6 5 11...
Page 10: ...FlexPAK 800 1000 DX 8 4C 4B 11 7 8 9 12 13 16 15 14 17 18 19 20 21 10...
Page 11: ...FlexPAK 800 1000 DX 9 1 2 3 4 5 6 7 14 13 12 11 9 8 10 5 A B 6 7...
Page 14: ...FlexPAK 800 1000 DX 12 11 12 14 13...
Page 15: ...FlexPAK 800 1000 DX 13 1 0m 39 4 A B C 16 17 15 Min 2 1m 83 A A A A C...
Page 40: ...FlexPAK 800 1000 DX EN 38...
Page 64: ...FlexPAK 800 1000 DX CS 62...
Page 88: ...FlexPAK 800 1000 DX DA 86...
Page 160: ...FlexPAK 800 1000 DX FI 158...
Page 280: ...FlexPAK 800 1000 DX NO 278...
Page 306: ...FlexPAK 800 1000 DX PL 304...
Page 341: ...FlexPAK 800 1000 DX 339 RU FlexPAK 800 1000 DX FlexPAK 800 1000 DX 5 1 9 10...
Page 348: ...FlexPAK 800 1000 DX RU 346 7 7 1 1 2 3 Program 4 Set Parameter 5 6 7 8 9 10...
Page 351: ...FlexPAK 800 1000 DX 349 RU 2 X1 13 X1 14 3 3 10 DIR 12 SSR 12 DIR 10 8 4 DO3 24 9...
Page 356: ...FlexPAK 800 1000 DX RU 354...
Page 402: ...FlexPAK 800 1000 DX CN 400...
Page 403: ......
Page 404: ...www nederman com...