4.11 External Line Triggerl
Input Settings for the External Line Trigger
Figure 4-11-1 External Line Trigger Settings (Image from GigEGrab)
4.11.1
External Line Trigger Input Signal Polarity Invert Settings
This register inverts the polarity of the external trigger signal.
・
register name
:
LineTriggerConfig_Inverter
・
setting value
:
0(Invert function OFF), 1(Invert Function ON)
4.11.2 External Line Trigger Output Enable/Disable
This register enables or disables the external trigger signal output.
・
register name
:
LineTriggerConfig_Ext_out
・
setting value
:
0 (Output Disabled), 1(Output Enabled)
4.11.3 External Line Trigger Input Terminate Enable/Disable
This register enables or disables the external trigger input terminator.
・
register name
:
LineTriggerConfig_Terminate
・
setting value
:
0(Terminate Disabled), 1(Terminate Enabled)
For terminate requirements, see 3.4 External Trigger Connecter.